Cardiac Implantable Electronic Device Lead-Induced Tricuspid Regurgitation

Background: Tricuspid regurgitation (TR) is a valvular heart disorder characterized by the backward flow of blood from the right ventricle into the right atrium during systole, due to incomplete closure of the tricuspid valve. While traditionally considered a benign condition, recent studies have highlighted its association with increased morbidity and mortality, particularly in moderate to severe cases. The treatment of bradyarrhythmias and heart failure has been greatly enhanced by Pacemakers, implanted cardioverter-defibrillators (ICDs), and cardiac resynchronization treatment (CRT) systems are examples of cardiac implantable electronic devices (CIEDs). However, the tricuspid valve (TV) is traversed by the transvenous leads needed for these devices, which may impair valve function. An increasingly common side effect is Lead-induced tricuspid regurgitation (LITR) is characterized by mechanical interference of the lead with chordal structures, subvalvular apparatus, or tricuspid leaflet coaptation. Tricuspid regurgitation may develop as a result, leading to right-sided heart failure, elevated morbidity, and decreased survival. LITR has a complex pathophysiology that includes fibrosis, entrapment, and lead impingement. LITR is still underdiagnosed and frequently undertreated, despite its clinical importance. Conclusion: CIED lead-induced tricuspid regurgitation is a clinically significant yet often overlooked complication. Early recognition through echocardiography, particularly with 3D imaging, is crucial for accurate diagnosis. Management strategies depend on the severity of regurgitation and patient symptoms, ranging from conservative monitoring to lead revision or surgical intervention. As the use of CIEDs continues to rise, a multidisciplinary approach to prevent, detect, and treat LITR is essential to improving patient outcomes and quality of life.

Authors

Institutions

Publication Details

Journal
Zagazig University Medical Journal
Published
2025-09-27
DOI
https://doi.org/10.21608/zumj.2025.418730.4142
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cardiac Implantable Electronic Device Lead-Induced Tricuspid Regurgitation

Sahar M. Talaat, Ismail Mohamed Ibrahim, Hisham Samir Roshdy, Tarek Ahmed Naguib
Zagazig University Medical Journal
Cardiac pacing and defibrillation studies
article

Cardiac Implantable Electronic Device Lead-Induced Tricuspid Regurgitation

Sahar M. Talaat, Ismail Mohamed Ibrahim, Hisham Samir Roshdy, Tarek Ahmed Naguib
article en

Abstract

Background: Tricuspid regurgitation (TR) is a valvular heart disorder characterized by the backward flow of blood from the right ventricle into the right atrium during systole, due to incomplete closure of the tricuspid valve. While traditionally considered a benign condition, recent studies have highlighted its association with increased morbidity and mortality, particularly in moderate to severe cases. The treatment of bradyarrhythmias and heart failure has been greatly enhanced by Pacemakers, implanted cardioverter-defibrillators (ICDs), and cardiac resynchronization treatment (CRT) systems are examples of cardiac implantable electronic devices (CIEDs). However, the tricuspid valve (TV) is traversed by the transvenous leads needed for these devices, which may impair valve function. An increasingly common side effect is Lead-induced tricuspid regurgitation (LITR) is characterized by mechanical interference of the lead with chordal structures, subvalvular apparatus, or tricuspid leaflet coaptation. Tricuspid regurgitation may develop as a result, leading to right-sided heart failure, elevated morbidity, and decreased survival. LITR has a complex pathophysiology that includes fibrosis, entrapment, and lead impingement. LITR is still underdiagnosed and frequently undertreated, despite its clinical importance. Conclusion: CIED lead-induced tricuspid regurgitation is a clinically significant yet often overlooked complication. Early recognition through echocardiography, particularly with 3D imaging, is crucial for accurate diagnosis. Management strategies depend on the severity of regurgitation and patient symptoms, ranging from conservative monitoring to lead revision or surgical intervention. As the use of CIEDs continues to rise, a multidisciplinary approach to prevent, detect, and treat LITR is essential to improving patient outcomes and quality of life.

Zagazig University Medical JournalVol. 0(0)
Zagazig University (EG)
Openalex Percentile: Top 59%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.