Advancements in Electromyography (EMG) Signal Processing and Classification Techniques for Prosthetic Hand Control Applications: A Comprehensive Review

Prosthetic hand control lies at the critical intersection of biomedical engineering and rehabilitation medicine, aiming to restore natural hand function in amputees through precise interpretation of neuromuscular signals. Electromyography (EMG) has become the predominant technique for achieving intuitive control, yet despite promising outcomes in research environments, significant challenges persist in translating these advances into reliable, real-world clinical applications. To assess the current state of the field, a systematic literature review was conducted in accordance with PRISMA guidelines, drawing from PubMed, IEEE Xplore, and Google Scholar. A total of 285 studies were initially identified, of which 52 met the inclusion criteria based on classification accuracy, real-time implementation feasibility, and clinical viability. The analysis revealed that deep learning techniques consistently outperformed traditional approaches, while the integration of multimodal data and the use of advanced preprocessing methods significantly improved system robustness. However, real-time implementation introduced critical performance trade-offs, particularly in terms of latency and power efficiency. Although EMG-based control systems have reached a stage of clinical viability, especially with the superior offline performance of deep learning models, successful deployment still requires hybrid strategies that can balance high accuracy (>90%), low power consumption (<2W), and rapid response times (<300ms). Persistent barriers, such as electrode stability degradation resulting in an 18–25% drop in accuracy, and inter-session variability, underscore the necessity for adaptive calibration mechanisms to ensure consistent, long-term performance and enable widespread.

Authors

Institutions

Publication Details

Journal
Industrial Technology Journal
Published
2025-09-22
DOI
https://doi.org/10.21608/itj.2025.402363.1033
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advancements in Electromyography (EMG) Signal Processing and Classification Techniques for Prosthetic Hand Control Applications: A Comprehensive Review

Ahmed El-Bialy, Hamed Anwer Ibrahim, Bassam A. Hemade, Wafaa N. Abdelrazik
Industrial Technology Journal
Muscle activation and electromyography studies
article

Advancements in Electromyography (EMG) Signal Processing and Classification Techniques for Prosthetic Hand Control Applications: A Comprehensive Review

Ahmed El-Bialy, Hamed Anwer Ibrahim, Bassam A. Hemade, Wafaa N. Abdelrazik
article en

Abstract

Prosthetic hand control lies at the critical intersection of biomedical engineering and rehabilitation medicine, aiming to restore natural hand function in amputees through precise interpretation of neuromuscular signals. Electromyography (EMG) has become the predominant technique for achieving intuitive control, yet despite promising outcomes in research environments, significant challenges persist in translating these advances into reliable, real-world clinical applications. To assess the current state of the field, a systematic literature review was conducted in accordance with PRISMA guidelines, drawing from PubMed, IEEE Xplore, and Google Scholar. A total of 285 studies were initially identified, of which 52 met the inclusion criteria based on classification accuracy, real-time implementation feasibility, and clinical viability. The analysis revealed that deep learning techniques consistently outperformed traditional approaches, while the integration of multimodal data and the use of advanced preprocessing methods significantly improved system robustness. However, real-time implementation introduced critical performance trade-offs, particularly in terms of latency and power efficiency. Although EMG-based control systems have reached a stage of clinical viability, especially with the superior offline performance of deep learning models, successful deployment still requires hybrid strategies that can balance high accuracy (>90%), low power consumption (<2W), and rapid response times (<300ms). Persistent barriers, such as electrode stability degradation resulting in an 18–25% drop in accuracy, and inter-session variability, underscore the necessity for adaptive calibration mechanisms to ensure consistent, long-term performance and enable widespread.

Industrial Technology JournalVol. 0(0)
Suez University (EG)
Openalex Percentile: Top 74%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.