Fine-Tuning an ISFET-Based Dual pH–Total Alkalinity Sensor for Operation in Seawater Using an Adjustable, Suspended Anode

In this study, we present a re-envisioned design of an ion-sensitive field-effect transistor (ISFET)-based solid-state sensor for measuring pH and total alkalinity of seawater with electrolytically generated titrant. The original design requires either custom nanofabrication of ISFET wafers or back-end processing of fully fabricated ISFETs. Instead, we assembled all "off-the-shelf" parts to demonstrate the same measurement principle but with the titrant-generating electrode suspended orthogonal to the pH-sensing region of the ISFET rather than being physically deposited on the face of the chip. This offers many benefits including (1) avoiding disruption the pH functionality of the ISFET; (2) enabling the assessment of anode-gate distance sensitivity from a single ISFET; and (3) exploration of different electrode geometries and composition without complex ISFET fabrication. In this study, we analyzed the sensitivity of the A<sub>T</sub> measurement to the spacing of the titrant-generating electrode (anode) to the pH-sensing region of the ISFET (gate) as well as sensitivity to the electric current applied to the anode at three seawater A<sub>T</sub> compositions. The greatest sensor resolution in seawater was achieved when operating at a low anode current (5 μA) and greater anode-gate distance (∼150 to 200 μm) for the suspended anode configuration. The suspended anode configuration also showed an improvement in equivalence point determination with sharper inflections relative to the on-chip anode configuration. By averaging (<i>N</i> = 5), a sensor error of 2.85 μmol kg<sup>-1</sup> was achieved over 131 measurements.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-09-28
DOI
https://doi.org/10.1021/acssensors.5c02765
Citations
1
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.74
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fine-Tuning an ISFET-Based Dual pH–Total Alkalinity Sensor for Operation in Seawater Using an Adjustable, Suspended Anode

Ellen M. Briggs, Todd R. Martz
1 citations
ACS Sensors
Analytical Chemistry and Sensors
0.74
article

Fine-Tuning an ISFET-Based Dual pH–Total Alkalinity Sensor for Operation in Seawater Using an Adjustable, Suspended Anode

Ellen M. Briggs, Todd R. Martz
article en
1 citations

Abstract

In this study, we present a re-envisioned design of an ion-sensitive field-effect transistor (ISFET)-based solid-state sensor for measuring pH and total alkalinity of seawater with electrolytically generated titrant. The original design requires either custom nanofabrication of ISFET wafers or back-end processing of fully fabricated ISFETs. Instead, we assembled all "off-the-shelf" parts to demonstrate the same measurement principle but with the titrant-generating electrode suspended orthogonal to the pH-sensing region of the ISFET rather than being physically deposited on the face of the chip. This offers many benefits including (1) avoiding disruption the pH functionality of the ISFET; (2) enabling the assessment of anode-gate distance sensitivity from a single ISFET; and (3) exploration of different electrode geometries and composition without complex ISFET fabrication. In this study, we analyzed the sensitivity of the A<sub>T</sub> measurement to the spacing of the titrant-generating electrode (anode) to the pH-sensing region of the ISFET (gate) as well as sensitivity to the electric current applied to the anode at three seawater A<sub>T</sub> compositions. The greatest sensor resolution in seawater was achieved when operating at a low anode current (5 μA) and greater anode-gate distance (∼150 to 200 μm) for the suspended anode configuration. The suspended anode configuration also showed an improvement in equivalence point determination with sharper inflections relative to the on-chip anode configuration. By averaging (<i>N</i> = 5), a sensor error of 2.85 μmol kg<sup>-1</sup> was achieved over 131 measurements.

ACS SensorsVol. 10(10)
Scripps Institution of Oceanography (US), University of California San Diego (US)
Openalex Percentile: Top 26%
Analytical Chemistry and Sensors
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.