Water-Holding Capacity of Clogged Granite Crushed Stone

Purpose: To investigate the water-holding capacity of granite crushed stone ballast, with a stone fraction ranging from 5 to 25 millimetres. Methods: The experimental procedure was conducted within a designated container to ascertain the water-retention capabilities and degree of water saturation of granite crushed stone that is used as the primary material in the construction of railway tracks. Laboratory tests were conducted utilising varying percentages of clogging agent, ranging from 5 to 25 millimetres (10%, 20, 30, and 40% by mass of aggregate), within the grain composition of the crushed stone. Results: The test results demonstrate that clogging of crushed stone with particles ranging from 5 to 25 mm does not exert a significant influence onits water-holding capacity and degree of water saturation. In the presence of up to 40% by weight of clogging agent with a size of 5–25 mm in the crushed stone grain, the moisture content increased by no more than 0.4%, and the degree of water saturation did not exceed 0.04 p.u. (percentage unit) in conditions of an active railway track. Practical significance: The clogging of crushed stone in a track ballast layer with 5–25 mm-size fractions and a mass percentage of up to 40% has negligible impact on the water-holding capacity and degree of water saturation. This phenomenon does not exert a substantial influence on the reduction of strength and deformation characteristics of the crushed stone.

Authors

Institutions

Publication Details

Journal
Bulletin of scientific research results
Published
2025-09-28
DOI
https://doi.org/10.20295/2223-9987-2025-3-7-20
Primary Topic
Geotechnical Engineering and Underground Structures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Water-Holding Capacity of Clogged Granite Crushed Stone

Aleksey Kolos, Ivan Igoshev
Bulletin of scientific research results
Geotechnical Engineering and Underground Structures
article

Water-Holding Capacity of Clogged Granite Crushed Stone

Aleksey Kolos, Ivan Igoshev
article en

Abstract

Purpose: To investigate the water-holding capacity of granite crushed stone ballast, with a stone fraction ranging from 5 to 25 millimetres. Methods: The experimental procedure was conducted within a designated container to ascertain the water-retention capabilities and degree of water saturation of granite crushed stone that is used as the primary material in the construction of railway tracks. Laboratory tests were conducted utilising varying percentages of clogging agent, ranging from 5 to 25 millimetres (10%, 20, 30, and 40% by mass of aggregate), within the grain composition of the crushed stone. Results: The test results demonstrate that clogging of crushed stone with particles ranging from 5 to 25 mm does not exert a significant influence onits water-holding capacity and degree of water saturation. In the presence of up to 40% by weight of clogging agent with a size of 5–25 mm in the crushed stone grain, the moisture content increased by no more than 0.4%, and the degree of water saturation did not exceed 0.04 p.u. (percentage unit) in conditions of an active railway track. Practical significance: The clogging of crushed stone in a track ballast layer with 5–25 mm-size fractions and a mass percentage of up to 40% has negligible impact on the water-holding capacity and degree of water saturation. This phenomenon does not exert a substantial influence on the reduction of strength and deformation characteristics of the crushed stone.

Bulletin of scientific research resultsVol. 2025(3)
Petersburg State Transport University (RU)
Openalex Percentile: Top 72%
Geotechnical Engineering and Underground Structures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Water-Holding Capacity of Clogged Granite Crushed Stone — Aleksey Kolos, Ivan Igoshev · Bulletin of scientific research results (2025) | TGRS Research Map | TGRS