Comparison of radial versus cartesian k-space sampling in T1-weighted MRI: image quality assessment for contrast-enhanced thoracic spine transverse imaging

Motion artifacts caused by respiration, cardiac pulsation, and vascular flow often degrade image quality in conventional contrast-enhanced transverse T1-weighted magnetic resonance imaging (MRI) of the thoracic spine, hindering lesion detection and characterization. Although radial k-space sampling sequences have demonstrated strong motion artifact suppression through non-Cartesian acquisition trajectories, their clinical value in contrast-enhanced thoracic spine MRI remains unverified. This study aimed to evaluate the clinical utility of the free-breathing radial k-space sampling sequence for contrast-enhanced transverse T1-weighted MRI of thoracic spine. Total of 48 patients with thoracic vertebral lesions enrolled in this prospectively study underwent contrast-enhanced thoracic spine examination on a 3T MRI scanner from July 2024 to March 2025. After contrast administration, three transverse sequences, including conventional two-dimensional T1-weighted imaging with modified Dixon turbo spin echo (2D T1WI-mDixon-TSE), breath-hold three-dimensional T1-weighted imaging with modified Dixon gradient echo (3D T1WI-mDixon-GRE), and free-breathing 3D volumetric accelerated navigator echo with extended dynamic range (3D VANE XD) were acquired. Signal-to-noise ratio (SNR) was measured at the central slice. Two radiologists independently scored artifact suppression, thoracic vertebra/lesion clarity and overall image quality using a 4-point Likert scale. The differences in SNR and subjective evaluation scores among above three sequences were compared and analyzed. The free-breathing 3D VANE XD and 3D T1WI-mDixon-GRE sequences achieved significantly higher SNR than 2D T1WI-mDixon-TSE sequence (both p < 0.01). In the subjective evaluation of artifact suppression, the free-breathing 3D VANE XD sequence also scored highest [3.90(3.81, 3.95)], followed by the breath-hold 3D T1WI-mDixon-GRE [3.55(3.50, 3.70)] and 2D T1WI-mDixon-TSE sequences [2.90(2.75, 3.08)]. For the clarity of thoracic vertebra and lesion, the free-breathing 3D VANE XD sequence scored significantly highest (both p < 0.01). And the overall image quality of free-breathing 3D VANE XD sequence was significantly best [3.90 (3.85, 3.95)] than the other two sequences (both p < 0.01). The free-breathing 3D VANE XD sequence significantly improved the image quality of contrast-enhanced transverse T1-weighted MRI for thoracic spine, supporting its integration into routine clinical practice.

Authors

Institutions

Publication Details

Journal
BMC Medical Imaging
Published
2025-09-26
DOI
https://doi.org/10.1186/s12880-025-01931-7
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of radial versus cartesian k-space sampling in T1-weighted MRI: image quality assessment for contrast-enhanced thoracic spine transverse imaging

Funan Wang, Liuhong Zhu, Xiaobo Qu, Jianjun Zhou et al.
BMC Medical Imaging
Advanced MRI Techniques and Applications
article

Comparison of radial versus cartesian k-space sampling in T1-weighted MRI: image quality assessment for contrast-enhanced thoracic spine transverse imaging

Funan Wang, Liuhong Zhu, Xiaobo Qu, Jianjun Zhou, Yanwei Wang, Weigen Yao, Haibo Liu
article en

Abstract

Motion artifacts caused by respiration, cardiac pulsation, and vascular flow often degrade image quality in conventional contrast-enhanced transverse T1-weighted magnetic resonance imaging (MRI) of the thoracic spine, hindering lesion detection and characterization. Although radial k-space sampling sequences have demonstrated strong motion artifact suppression through non-Cartesian acquisition trajectories, their clinical value in contrast-enhanced thoracic spine MRI remains unverified. This study aimed to evaluate the clinical utility of the free-breathing radial k-space sampling sequence for contrast-enhanced transverse T1-weighted MRI of thoracic spine. Total of 48 patients with thoracic vertebral lesions enrolled in this prospectively study underwent contrast-enhanced thoracic spine examination on a 3T MRI scanner from July 2024 to March 2025. After contrast administration, three transverse sequences, including conventional two-dimensional T1-weighted imaging with modified Dixon turbo spin echo (2D T1WI-mDixon-TSE), breath-hold three-dimensional T1-weighted imaging with modified Dixon gradient echo (3D T1WI-mDixon-GRE), and free-breathing 3D volumetric accelerated navigator echo with extended dynamic range (3D VANE XD) were acquired. Signal-to-noise ratio (SNR) was measured at the central slice. Two radiologists independently scored artifact suppression, thoracic vertebra/lesion clarity and overall image quality using a 4-point Likert scale. The differences in SNR and subjective evaluation scores among above three sequences were compared and analyzed. The free-breathing 3D VANE XD and 3D T1WI-mDixon-GRE sequences achieved significantly higher SNR than 2D T1WI-mDixon-TSE sequence (both p < 0.01). In the subjective evaluation of artifact suppression, the free-breathing 3D VANE XD sequence also scored highest [3.90(3.81, 3.95)], followed by the breath-hold 3D T1WI-mDixon-GRE [3.55(3.50, 3.70)] and 2D T1WI-mDixon-TSE sequences [2.90(2.75, 3.08)]. For the clarity of thoracic vertebra and lesion, the free-breathing 3D VANE XD sequence scored significantly highest (both p < 0.01). And the overall image quality of free-breathing 3D VANE XD sequence was significantly best [3.90 (3.85, 3.95)] than the other two sequences (both p < 0.01). The free-breathing 3D VANE XD sequence significantly improved the image quality of contrast-enhanced transverse T1-weighted MRI for thoracic spine, supporting its integration into routine clinical practice.

BMC Medical ImagingVol. 25(1)
Xiamen University (CN), Zhongshan Hospital of Xiamen University (CN), Zhongshan Hospital (CN), Ningbo University Affiliated Hospital (CN), The Second Affiliated Hospital of Xiamen Medical College
Openalex Percentile: Top 60%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.