Real-Time Motion Compensation for Dynamic Dental Implant Surgery

<b>Background</b>: Accurate and stable instrument positioning is critical in dental implant procedures, particularly in anatomically constrained regions. Conventional navigation systems assume a static patient head, limiting adaptability in dynamic surgical conditions. This study proposes and validates a real-time motion compensation framework that integrates optical motion tracking with a collaborative robot to maintain tool alignment despite patient head movement. <b>Methods</b>: A six-camera OptiTrack Prime 13 system tracked rigid markers affixed to a 3D-printed human head model. Real-time head pose data were streamed to a Kuka LBR iiwa robot, which guided the implant handpiece to maintain alignment with a predefined target. Motion compensation was achieved through inverse trajectory computation and second-order Butterworth filtering to approximate realistic robotic response. Controlled experiments were performed using the MAiRA Pro M robot to impose precise motion patterns, including pure rotations (±30° at 10-40°/s), pure translations (±50 mm at 5-30 mm/s), and combined sinusoidal motions. Each motion profile was repeated ten times to evaluate intra-trial repeatability and dynamic response. <b>Results</b>: The system achieved consistent pose tracking errors below 0.2 mm, tool center point (TCP) deviations under 1.5 mm across all motion domains, and an average latency of ~25 ms. Overshoot remained minimal, with effective damping during motion reversal phases. The robot demonstrated stable and repeatable compensation behavior across all experimental conditions. <b>Conclusions</b>: The proposed framework provides reliable real-time motion compensation for dental implant procedures, maintaining high positional accuracy and stability in the presence of head movement. These results support its potential for enhancing surgical safety and precision in dynamic clinical environments.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-09-12
DOI
https://doi.org/10.3390/jcm14186429
Citations
2
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
3.58

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-Time Motion Compensation for Dynamic Dental Implant Surgery

R Mocan, Mihaela Hedeșiu, Doina Pîslă, Călin Vaida et al.
2 citations
Journal of Clinical Medicine
Dental Implant Techniques and Outcomes
3.58
article

Real-Time Motion Compensation for Dynamic Dental Implant Surgery

R Mocan, Mihaela Hedeșiu, Doina Pîslă, Călin Vaida, Paul Tucan, Daria Pisla, Andrei Cailean, Cristian Dinu, Vasile Bulbucan
article en
2 citations

Abstract

<b>Background</b>: Accurate and stable instrument positioning is critical in dental implant procedures, particularly in anatomically constrained regions. Conventional navigation systems assume a static patient head, limiting adaptability in dynamic surgical conditions. This study proposes and validates a real-time motion compensation framework that integrates optical motion tracking with a collaborative robot to maintain tool alignment despite patient head movement. <b>Methods</b>: A six-camera OptiTrack Prime 13 system tracked rigid markers affixed to a 3D-printed human head model. Real-time head pose data were streamed to a Kuka LBR iiwa robot, which guided the implant handpiece to maintain alignment with a predefined target. Motion compensation was achieved through inverse trajectory computation and second-order Butterworth filtering to approximate realistic robotic response. Controlled experiments were performed using the MAiRA Pro M robot to impose precise motion patterns, including pure rotations (±30° at 10-40°/s), pure translations (±50 mm at 5-30 mm/s), and combined sinusoidal motions. Each motion profile was repeated ten times to evaluate intra-trial repeatability and dynamic response. <b>Results</b>: The system achieved consistent pose tracking errors below 0.2 mm, tool center point (TCP) deviations under 1.5 mm across all motion domains, and an average latency of ~25 ms. Overshoot remained minimal, with effective damping during motion reversal phases. The robot demonstrated stable and repeatable compensation behavior across all experimental conditions. <b>Conclusions</b>: The proposed framework provides reliable real-time motion compensation for dental implant procedures, maintaining high positional accuracy and stability in the presence of head movement. These results support its potential for enhancing surgical safety and precision in dynamic clinical environments.

Journal of Clinical MedicineVol. 14(18)
Technical University of Cluj-Napoca (RO), Iuliu Hațieganu University of Medicine and Pharmacy (RO)
European Commission, Universitatea de Medicină şi Farmacie Iuliu Haţieganu Cluj-Napoca
Openalex Percentile: Top 7%
Dental Implant Techniques and Outcomes
3.58
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.