An Engineered Au-MXene Sorption Trap Enables Dual-Channel Ultrafast and Selective Detection of Trace Gaseous Elemental Mercury

Accurate detection of trace atmospheric mercury is critical for toxicological assessment and environmental protection. However, achieving parts per billion-level sensitivity with high selectivity between gaseous elemental mercury (Hg<sup>0</sup>) and oxidized mercury (Hg<sup>2+</sup>) remains a significant challenge. Here, we present a novel dual-channel enrichment trap system that selectively captures Hg<sup>0</sup> by using a layered Au-MXene (Ti<sub>3</sub>C<sub>2</sub>T<sub><i>x</i></sub>) composite as the sorption trap. This composite demonstrates exceptional selectivity for Hg<sup>0</sup>, with a selectivity ratio of up to 76.7 over Hg<sup>2+</sup>, and achieves 99.7% ± 0.3% (<i>n</i> = 3) sorption efficiency for ppb-level Hg<sup>0</sup> within 30 min at room temperature. Complete desorption is achieved in just 90 s at 300 °C, demonstrating a response time of 45 s for Hg<sup>0</sup> detection through the dual-electrothermal Hg<sup>0</sup> channel. The Au-Ti<sub>3</sub>C<sub>2</sub>T<sub><i>x</i></sub> preconcentration cartridge exhibits excellent moisture resistance, high-temperature stability, and long-term durability. Density functional theory (DFT) calculations reveal that the built-in electric field at the Au-Ti<sub>3</sub>C<sub>2</sub>T<sub><i>x</i></sub> interface accelerates electron transfer, reducing preconcentration and regeneration times. This technology integrates seamlessly with the cold vapor atomic absorption spectrophotometer (CVAAS) method to form a mercury dual-channel continuous emission measurement system (Hg DCEMS), ensuring highly selective and precise trace Hg<sup>0</sup> detection. This advancement provides a device for accurately measuring the Hg<sup>0</sup> concentration, enabling better mercury pollution control.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-09-27
DOI
https://doi.org/10.1021/acs.analchem.5c02853
Primary Topic
MXene and MAX Phase Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Engineered Au-MXene Sorption Trap Enables Dual-Channel Ultrafast and Selective Detection of Trace Gaseous Elemental Mercury

Zan Qu, Naiqiang Yan, Qingyan Fu, Wenjun Huang et al.
Analytical Chemistry
MXene and MAX Phase Materials
article

An Engineered Au-MXene Sorption Trap Enables Dual-Channel Ultrafast and Selective Detection of Trace Gaseous Elemental Mercury

Zan Qu, Naiqiang Yan, Qingyan Fu, Wenjun Huang, Qianxuan Zhang, Jia Chen, Yiqi Feng, Haomiao Xu, Bing Pei, Qinyuan Hong, Menggai Jiao, Li Yang
article en

Abstract

Accurate detection of trace atmospheric mercury is critical for toxicological assessment and environmental protection. However, achieving parts per billion-level sensitivity with high selectivity between gaseous elemental mercury (Hg<sup>0</sup>) and oxidized mercury (Hg<sup>2+</sup>) remains a significant challenge. Here, we present a novel dual-channel enrichment trap system that selectively captures Hg<sup>0</sup> by using a layered Au-MXene (Ti<sub>3</sub>C<sub>2</sub>T<sub><i>x</i></sub>) composite as the sorption trap. This composite demonstrates exceptional selectivity for Hg<sup>0</sup>, with a selectivity ratio of up to 76.7 over Hg<sup>2+</sup>, and achieves 99.7% ± 0.3% (<i>n</i> = 3) sorption efficiency for ppb-level Hg<sup>0</sup> within 30 min at room temperature. Complete desorption is achieved in just 90 s at 300 °C, demonstrating a response time of 45 s for Hg<sup>0</sup> detection through the dual-electrothermal Hg<sup>0</sup> channel. The Au-Ti<sub>3</sub>C<sub>2</sub>T<sub><i>x</i></sub> preconcentration cartridge exhibits excellent moisture resistance, high-temperature stability, and long-term durability. Density functional theory (DFT) calculations reveal that the built-in electric field at the Au-Ti<sub>3</sub>C<sub>2</sub>T<sub><i>x</i></sub> interface accelerates electron transfer, reducing preconcentration and regeneration times. This technology integrates seamlessly with the cold vapor atomic absorption spectrophotometer (CVAAS) method to form a mercury dual-channel continuous emission measurement system (Hg DCEMS), ensuring highly selective and precise trace Hg<sup>0</sup> detection. This advancement provides a device for accurately measuring the Hg<sup>0</sup> concentration, enabling better mercury pollution control.

Analytical ChemistryVol. 97(39)
Shanghai Jiao Tong University (CN), Ministry of Ecology and Environment (CN), Beijing Founder Electronics (China) (CN), Zhejiang Environmental Monitoring Center (CN), Shanghai Academy of Environmental Sciences (CN), Shanghai Institute of Pollution Control and Ecological Security
Openalex Percentile: Top 80%
MXene and MAX Phase Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.