Multi-Signal Acquisition System for Continuous Blood Pressure Monitoring

Continuous blood pressure (BP) monitoring is essential for the early detection and prevention of cardiovascular diseases like hypertension. Recently, interest in continuous BP estimation systems and algorithms has grown. Various physiological signals reflect BP variations from different perspectives, and combining multiple signals can enhance the accuracy of BP measurements. However, research integrating electrocardiogram (ECG), photoplethysmography (PPG), and impedance cardiography (ICG) signals for BP monitoring remains limited, with related technologies still in early development. A major challenge is the increased system complexity associated with acquiring multiple signals simultaneously, along with the difficulty of efficiently extracting and integrating key features for accurate BP estimation. To address this, we developed a BP monitoring system that can synchronously acquire and process ECG, PPG, and ICG signals. Optimizing the circuit design allowed ECG and ICG modules to share electrodes, reducing components and improving compactness. Using this system, we collected 400 min of signals from 40 healthy subjects, yielding 4390 records. Experiments were conducted to evaluate the system's performance in BP estimation. The results demonstrated that combining pulse wave analysis features with the XGBoost model yielded the most accurate BP predictions. Specifically, the mean absolute error for systolic blood pressure was 3.76 ± 3.98 mmHg, and for diastolic blood pressure, it was 2.71 ± 2.57 mmHg, both of which achieved grade A performance under the BHS standard. These results are comparable to or better than existing studies based on multi-signal methods. These findings suggest that the proposed system offers an efficient and practical solution for BP monitoring.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-09-21
DOI
https://doi.org/10.3390/s25185910
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-Signal Acquisition System for Continuous Blood Pressure Monitoring

Shenman Qiu, Li Hai Tan, Dan Guo, Jintao Chen et al.
Sensors
ECG Monitoring and Analysis
article

Multi-Signal Acquisition System for Continuous Blood Pressure Monitoring

Shenman Qiu, Li Hai Tan, Dan Guo, Jintao Chen, Jinting Ma, Naiwen Zhang, Yu Zhang
article en

Abstract

Continuous blood pressure (BP) monitoring is essential for the early detection and prevention of cardiovascular diseases like hypertension. Recently, interest in continuous BP estimation systems and algorithms has grown. Various physiological signals reflect BP variations from different perspectives, and combining multiple signals can enhance the accuracy of BP measurements. However, research integrating electrocardiogram (ECG), photoplethysmography (PPG), and impedance cardiography (ICG) signals for BP monitoring remains limited, with related technologies still in early development. A major challenge is the increased system complexity associated with acquiring multiple signals simultaneously, along with the difficulty of efficiently extracting and integrating key features for accurate BP estimation. To address this, we developed a BP monitoring system that can synchronously acquire and process ECG, PPG, and ICG signals. Optimizing the circuit design allowed ECG and ICG modules to share electrodes, reducing components and improving compactness. Using this system, we collected 400 min of signals from 40 healthy subjects, yielding 4390 records. Experiments were conducted to evaluate the system's performance in BP estimation. The results demonstrated that combining pulse wave analysis features with the XGBoost model yielded the most accurate BP predictions. Specifically, the mean absolute error for systolic blood pressure was 3.76 ± 3.98 mmHg, and for diastolic blood pressure, it was 2.71 ± 2.57 mmHg, both of which achieved grade A performance under the BHS standard. These results are comparable to or better than existing studies based on multi-signal methods. These findings suggest that the proposed system offers an efficient and practical solution for BP monitoring.

SensorsVol. 25(18)
Jinan University (CN), Shenzhen University (CN), Shenzhen Institute of Neuroscience (CN)
Natural Science Foundation of Shenzhen City, Basic and Applied Basic Research Foundation of Guangdong Province
Openalex Percentile: Top 60%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.