Development of a Digital Sialometry Device for Minor Salivary Glands With Enhanced Volume Range and Precision: A Technical Report

To address the measurement limitations of a previously developed electronic device for sialometry of minor salivary glands, an improved version was developed to enable accurate assessment of larger saliva volumes. The device estimates saliva volume by calculating the electrical impedance of a filter paper that has absorbed saliva, using a microcontroller-based digital method. A calibration curve was generated using physiological saline, adjusted to match the conductivity of human labial gland saliva. The improved device can measure saliva volumes up to 9.0 μL using a 10 mm square filter paper, significantly expanding the measurable range compared to the previous version. This enhancement increases both the precision and applicability of minor salivary gland sialometry, contributing to a more reliable assessment of salivary function in clinical and research settings.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-09-28
DOI
https://doi.org/10.7759/cureus.93385
Primary Topic
Salivary Gland Disorders and Functions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Digital Sialometry Device for Minor Salivary Glands With Enhanced Volume Range and Precision: A Technical Report

Takanori Hatakeyama, Masahiro Iikubo, Shizuko Satoh‐Kuriwada, H. Kachi et al.
Cureus
Salivary Gland Disorders and Functions
article

Development of a Digital Sialometry Device for Minor Salivary Glands With Enhanced Volume Range and Precision: A Technical Report

Takanori Hatakeyama, Masahiro Iikubo, Shizuko Satoh‐Kuriwada, H. Kachi, Toru Ogawa, Satoshi GOTOH, Takeo Otabe
article en

Abstract

To address the measurement limitations of a previously developed electronic device for sialometry of minor salivary glands, an improved version was developed to enable accurate assessment of larger saliva volumes. The device estimates saliva volume by calculating the electrical impedance of a filter paper that has absorbed saliva, using a microcontroller-based digital method. A calibration curve was generated using physiological saline, adjusted to match the conductivity of human labial gland saliva. The improved device can measure saliva volumes up to 9.0 μL using a 10 mm square filter paper, significantly expanding the measurable range compared to the previous version. This enhancement increases both the precision and applicability of minor salivary gland sialometry, contributing to a more reliable assessment of salivary function in clinical and research settings.

CureusVol. 17(9)
Tohoku University (JP), Tohoku University Hospital (JP), Saiseikai Utsunomiya hospital (JP)
Openalex Percentile: Top 67%
Salivary Gland Disorders and Functions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.