Giant Papillary Conjunctivitis Induced by Sutures after XEN Stent Implantation

Purpose: We present a case of giant papillary conjunctivitis (GPC) induced by sutures used during XEN gel stent implantation.Case summary: A 67-year-old man underwent XEN gel stent implantation in his right eye for uncontrolled glaucoma. After surgery, intraocular pressure (IOP) was maintained below 15 mmHg. However, eight months postoperatively, the IOP increased to 24 mmHg, and the patient reported a foreign body sensation. The 10-0 nylon suture used during stent implantation was exposed on the conjunctiva, and marked papillary hypertrophy was observed in the upper palpebral conjunctiva. Following removal of the suture material, the papillary hypertrophy resolved, and IOP decreased to 17 mmHg.Conclusions: Retained sutures after glaucoma surgery can induce giant papillary conjunctivitis, and the associated hypertrophy may affect filtration bleb function, leading to elevated IOP. This risk is heightened when devices, such as the XEN stent, are positioned superficially in the subconjunctiva, requiring careful suture management and timely removal.

Authors

Institutions

Publication Details

Journal
Annals of Optometry and Contact Lens
Published
2025-09-25
DOI
https://doi.org/10.52725/aocl.2025.24.3.150
Primary Topic
Retinal and Macular Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Giant Papillary Conjunctivitis Induced by Sutures after XEN Stent Implantation

Kyoo Won Lee, Sam Seo, Sang Eun Lee, H Sung
Annals of Optometry and Contact Lens
Retinal and Macular Surgery
article

Giant Papillary Conjunctivitis Induced by Sutures after XEN Stent Implantation

Kyoo Won Lee, Sam Seo, Sang Eun Lee, H Sung
article en

Abstract

Purpose: We present a case of giant papillary conjunctivitis (GPC) induced by sutures used during XEN gel stent implantation.Case summary: A 67-year-old man underwent XEN gel stent implantation in his right eye for uncontrolled glaucoma. After surgery, intraocular pressure (IOP) was maintained below 15 mmHg. However, eight months postoperatively, the IOP increased to 24 mmHg, and the patient reported a foreign body sensation. The 10-0 nylon suture used during stent implantation was exposed on the conjunctiva, and marked papillary hypertrophy was observed in the upper palpebral conjunctiva. Following removal of the suture material, the papillary hypertrophy resolved, and IOP decreased to 17 mmHg.Conclusions: Retained sutures after glaucoma surgery can induce giant papillary conjunctivitis, and the associated hypertrophy may affect filtration bleb function, leading to elevated IOP. This risk is heightened when devices, such as the XEN stent, are positioned superficially in the subconjunctiva, requiring careful suture management and timely removal.

Annals of Optometry and Contact LensVol. 24(3)
Nune Eye Hospital (KR)
Openalex Percentile: Top 60%
Retinal and Macular Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Giant Papillary Conjunctivitis Induced by Sutures after XEN Stent Implantation — Kyoo Won Lee, Sam Seo, et al. · Annals of Optometry and Contact Lens (2025) | TGRS Research Map | TGRS