Low‐Frequency Oscillation Suppression of Pulse Train Controlled Cuk Converter Operating in Continuous Conduction Mode

ABSTRACT The inductor current and output voltage of pulse train (PT) controlled switching converters in continuous conduction mode (CCM) suffer undesirable low‐frequency oscillation; thus, the steady state performance and transient performance will be affected seriously. Up to now, most previous works on PT control mainly focus on low‐order switching converters, with few research works reported on high‐order switching converters. In this paper, taking conventional Cuk converter as an example, the energy model based on energy balance for analyzing the low‐frequency oscillation of PT controlled high‐order switching converters is established. In order to suppress low‐frequency oscillation and achieve fast transient response, an improved Cuk converter with PT control is further proposed. The operation principle of PT controlled improved Cuk converter operating in CCM and the mechanism of suppressing low‐frequency oscillation are investigated in detail. The parameter design considerations of improved Cuk converter are also given. Finally, the experimental results are presented to verify the effectiveness of the proposed method and theoretical analysis.

Authors

Institutions

Publication Details

Journal
International Journal of Circuit Theory and Applications
Published
2025-09-27
DOI
https://doi.org/10.1002/cta.70151
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low‐Frequency Oscillation Suppression of Pulse Train Controlled Cuk Converter Operating in Continuous Conduction Mode

Ze Liu, Yingjie He, Guohua Zhou, Yanyan Jin et al.
International Journal of Circuit Theory and Applications
Advanced DC-DC Converters
article

Low‐Frequency Oscillation Suppression of Pulse Train Controlled Cuk Converter Operating in Continuous Conduction Mode

Ze Liu, Yingjie He, Guohua Zhou, Yanyan Jin, Yue Wang
article en

Abstract

ABSTRACT The inductor current and output voltage of pulse train (PT) controlled switching converters in continuous conduction mode (CCM) suffer undesirable low‐frequency oscillation; thus, the steady state performance and transient performance will be affected seriously. Up to now, most previous works on PT control mainly focus on low‐order switching converters, with few research works reported on high‐order switching converters. In this paper, taking conventional Cuk converter as an example, the energy model based on energy balance for analyzing the low‐frequency oscillation of PT controlled high‐order switching converters is established. In order to suppress low‐frequency oscillation and achieve fast transient response, an improved Cuk converter with PT control is further proposed. The operation principle of PT controlled improved Cuk converter operating in CCM and the mechanism of suppressing low‐frequency oscillation are investigated in detail. The parameter design considerations of improved Cuk converter are also given. Finally, the experimental results are presented to verify the effectiveness of the proposed method and theoretical analysis.

International Journal of Circuit Theory and Applications
Chengdu University of Information Technology (CN), Chengdu Institute of Information Technology (China) (CN), Silergy (China) (CN), Chengdu University (CN), Chengdu Technological University, Qingdao University of Technology (CN), Southwest Jiaotong University (CN)
Openalex Percentile: Top 74%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Low‐Frequency Oscillation Suppression of Pulse Train Controlled Cuk Converter Operating in Continuous Conduction Mode — Ze Liu, Yingjie He, et al. · International Journal of Circuit Theory and Applications (2025) | TGRS Research Map | TGRS