Real-time monitoring and characterization of thin film drug delivery systems using optical coherence tomography

The development of drug delivery systems demands close attention to product quality and consistency of quality attributes to guarantee reproducibility in fabrication, performance and therapeutic effectiveness. While some methods exist for monitoring in-line manufacturing, these methods are limited in terms of spatial resolution or depth penetration, which can lead to inconsistent characterization. Furthermore, conventional static characterization methods often lack the ability to monitor time-dependent changes within drug delivery systems. This limits their effectiveness in capturing dynamic processes such as swelling, disintegration, and drug release, underscoring the need for advanced techniques that offer reliable, high-resolution, and depth-specific insights into these mechanisms over time. Optical coherence tomography (OCT) is a non-invasive, high-resolution imaging technique which shows promise for comprehensive characterization of structural and dynamic characterization of drug delivery systems. In this study, we explore applications of OCT to structural and dynamic characterization of thin film drug delivery systems. We demonstrate that OCT can be used to non-destructively monitor the spatial variation of the refractive index and thickness of thin films, providing crucial feedback for quality control and ensuring standardized doses in individual film units. Further, we demonstrate that OCT can be used to monitor the dissolution dynamics, enabling characterization of time-controlled release mechanisms. These results suggest that OCT has the potential to enhance thin-film characterization by enabling more precise monitoring of critical quality attributes, which can contribute to improved manufacturing consistency and better control over the uniformity of the dose in each film unit.

Authors

Institutions

Publication Details

Journal
International Journal of Pharmaceutics
Published
2025-09-27
DOI
https://doi.org/10.1016/j.ijpharm.2025.126201
Citations
2
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-time monitoring and characterization of thin film drug delivery systems using optical coherence tomography

Nazanin Zanjanizadeh Ezazi, Gavrielle R. Untracht, Line Hagner Nielsen, Peter E. Andersen et al.
2 citations
International Journal of Pharmaceutics
Optical Coherence Tomography Applications
1.35
article

Real-time monitoring and characterization of thin film drug delivery systems using optical coherence tomography

Nazanin Zanjanizadeh Ezazi, Gavrielle R. Untracht, Line Hagner Nielsen, Peter E. Andersen, Eleftheria Pantazoglou, Johan Barfoed
article en
2 citations

Abstract

The development of drug delivery systems demands close attention to product quality and consistency of quality attributes to guarantee reproducibility in fabrication, performance and therapeutic effectiveness. While some methods exist for monitoring in-line manufacturing, these methods are limited in terms of spatial resolution or depth penetration, which can lead to inconsistent characterization. Furthermore, conventional static characterization methods often lack the ability to monitor time-dependent changes within drug delivery systems. This limits their effectiveness in capturing dynamic processes such as swelling, disintegration, and drug release, underscoring the need for advanced techniques that offer reliable, high-resolution, and depth-specific insights into these mechanisms over time. Optical coherence tomography (OCT) is a non-invasive, high-resolution imaging technique which shows promise for comprehensive characterization of structural and dynamic characterization of drug delivery systems. In this study, we explore applications of OCT to structural and dynamic characterization of thin film drug delivery systems. We demonstrate that OCT can be used to non-destructively monitor the spatial variation of the refractive index and thickness of thin films, providing crucial feedback for quality control and ensuring standardized doses in individual film units. Further, we demonstrate that OCT can be used to monitor the dissolution dynamics, enabling characterization of time-controlled release mechanisms. These results suggest that OCT has the potential to enhance thin-film characterization by enabling more precise monitoring of critical quality attributes, which can contribute to improved manufacturing consistency and better control over the uniformity of the dose in each film unit.

International Journal of PharmaceuticsVol. 685
Technical University of Denmark (DK)
Openalex Percentile: Top 17%
Optical Coherence Tomography Applications
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.