Evaluation of a fully automated assay for the measurement of plasma pTau217 and a composite score integrating the ratio Aβ1-42/1-40 as biomarkers of Alzheimer’s disease

Plasma phosphorylated Tau217 (pTau217) represents a sensitive blood-based biomarker for Alzheimer’s disease (AD). This study investigated the performance of plasma pTau217 alone and as a composite score (Aβ1-40/Aβ1-42*pTau217) for detecting low Aβ1-42/1-40 in cerebrospinal fluid (CSF) as a surrogate marker of brain β-amyloid pathological changes. We analysed plasma samples from 82 pre-selected participants who were dichotomized according to their CSF Aβ42/40 ratio after data-driven cutoff determination by Gaussian mixture modelling. The study cohort included patients in very early disease stages with mild cognitive impairment (MCI) due to AD and mild dementia due to AD in the Aβ-positive group and MCI due to other causes and mild dementia due to other causes in the Aβ-negative group. Concentrations of plasma pTau181 and pTau217 were determined on the fully automated LUMIPULSE platform. Additionally, plasma Aβ1-42/1-40 and pTau217 were assessed after consecutive Aβ- and Tau-immunoprecipitations (IPs). Corrections for age and sex effects in primary variables were done using a multivariate linear model on a logarithmic scale. Results are reported using both adjusted and unadjusted values. After adjustment for age and sex, median plasma pTau217 was increased by 203% in participants with low CSF Aβ1-42/1-40 (i.e. Aβ-positive), while pTau181 was increased by only 61%. PTau217 showed a larger area under the receiver operating characteristics curve (AUC) of 0.88 in identifying Aβ-positive individuals compared to plasma pTau181 (AUC: 0.78). Plasma Aβ1-42/1-40 ratio in Aβ-IP eluates (adjusted for age and sex) was decreased by only 10%, and the standardized effect size (Cohen´s d) was smaller than that of pTau217. Tau-IP did not improve the performance of the pTau217 assay (p = 0.568, DeLong test). However, the Aβ1-40/Aβ1-42*pTau217 ratio following immunoprecipitations appeared to outperform the single blood biomarkers. PTau217 as measured with the fully automated Lumipulse G pTau217 Plasma < RUO > assay demonstrated high accuracy for detecting low CSF Aβ1-42/1-40 and appears to represent a particularly attractive biomarker for future implementation in clinical practice. Furthermore, the composite score Aβ1-40/Aβ1-42*pTau217 showed promise for enhancing the blood-based early and differential diagnosis of AD.

Authors

Institutions

Publication Details

Journal
European Archives of Psychiatry and Clinical Neuroscience
Published
2025-09-27
DOI
https://doi.org/10.1007/s00406-025-02123-8
Citations
1
Primary Topic
Dementia and Cognitive Impairment Research
Type
article
Field-Weighted Citation Impact
1.47
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of a fully automated assay for the measurement of plasma pTau217 and a composite score integrating the ratio Aβ1-42/1-40 as biomarkers of Alzheimer’s disease

Jens Wiltfang, Andreas Steiert, Niels Hansen, Johannes Schuchhardt et al.
1 citations
European Archives of Psychiatry and Clinical Neuroscience
Dementia and Cognitive Impairment Research
1.47
article

Evaluation of a fully automated assay for the measurement of plasma pTau217 and a composite score integrating the ratio Aβ1-42/1-40 as biomarkers of Alzheimer’s disease

Jens Wiltfang, Andreas Steiert, Niels Hansen, Johannes Schuchhardt, Hans‐Wolfgang Klafki, Dirk Osterloh, Hermann Esselmann, Ingolf Lachmann, Bárbara Morgado, Katharina Waniek, Chris Bauer
article en
1 citations

Abstract

Plasma phosphorylated Tau217 (pTau217) represents a sensitive blood-based biomarker for Alzheimer’s disease (AD). This study investigated the performance of plasma pTau217 alone and as a composite score (Aβ1-40/Aβ1-42*pTau217) for detecting low Aβ1-42/1-40 in cerebrospinal fluid (CSF) as a surrogate marker of brain β-amyloid pathological changes. We analysed plasma samples from 82 pre-selected participants who were dichotomized according to their CSF Aβ42/40 ratio after data-driven cutoff determination by Gaussian mixture modelling. The study cohort included patients in very early disease stages with mild cognitive impairment (MCI) due to AD and mild dementia due to AD in the Aβ-positive group and MCI due to other causes and mild dementia due to other causes in the Aβ-negative group. Concentrations of plasma pTau181 and pTau217 were determined on the fully automated LUMIPULSE platform. Additionally, plasma Aβ1-42/1-40 and pTau217 were assessed after consecutive Aβ- and Tau-immunoprecipitations (IPs). Corrections for age and sex effects in primary variables were done using a multivariate linear model on a logarithmic scale. Results are reported using both adjusted and unadjusted values. After adjustment for age and sex, median plasma pTau217 was increased by 203% in participants with low CSF Aβ1-42/1-40 (i.e. Aβ-positive), while pTau181 was increased by only 61%. PTau217 showed a larger area under the receiver operating characteristics curve (AUC) of 0.88 in identifying Aβ-positive individuals compared to plasma pTau181 (AUC: 0.78). Plasma Aβ1-42/1-40 ratio in Aβ-IP eluates (adjusted for age and sex) was decreased by only 10%, and the standardized effect size (Cohen´s d) was smaller than that of pTau217. Tau-IP did not improve the performance of the pTau217 assay (p = 0.568, DeLong test). However, the Aβ1-40/Aβ1-42*pTau217 ratio following immunoprecipitations appeared to outperform the single blood biomarkers. PTau217 as measured with the fully automated Lumipulse G pTau217 Plasma < RUO > assay demonstrated high accuracy for detecting low CSF Aβ1-42/1-40 and appears to represent a particularly attractive biomarker for future implementation in clinical practice. Furthermore, the composite score Aβ1-40/Aβ1-42*pTau217 showed promise for enhancing the blood-based early and differential diagnosis of AD.

European Archives of Psychiatry and Clinical Neuroscience
German Center for Neurodegenerative Diseases (DE), MicroDiscovery (Germany) (DE), University of Aveiro (PT), University of Göttingen (DE)
Openalex Percentile: Top 15%
Dementia and Cognitive Impairment Research
1.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.