The Mismatch Negativity Compared: <scp>EEG</scp>, <scp>SQUID</scp>‐<scp>MEG</scp>, and Novel <scp><sup>4</sup>Helium</scp>‐<scp>OPMs</scp>

Magneto-encephalography (MEG) provides a higher spatial resolution than electro-encephalography (EEG) to measure human auditory responses. However, conventional cryogenic MEG systems (SQUID-MEG) suffer from severe technological restrictions limiting, for instance, routine clinical use. Fortunately, a new generation of MEG sensors, optically pumped magnetometers (OPMs), has been developed to bridge the gap, combining the wearability of EEG with the benefits of MEG signal acquisition. We aim to assess their potential for studying auditory mismatch processing. The auditory mismatch negativity (MMN) is a well-characterized evoked component observable using a passive oddball paradigm with two-tone sound sequences. It has been extensively described using both EEG and MEG and is part of many EEG-based clinical applications, such as the assessment of patients with disorders of consciousness. MMN is therefore a relevant candidate to evaluate OPM performance. We use recently developed Helium-OPMs, which are high dynamic range MEG sensors that operate at room temperature. We compare their performance with cryogenic SQUID-MEG and EEG in a passive frequency oddball paradigm. Results show a significant MMN across subjects in all modalities as well as a high temporal similarity between modalities. Signal-to-noise ratios were also similar, and detection of significant individual MMN (within-subjects) using the OPM system was equal to or better than EEG. Given that the OPM system tested here is a prototype comprised of only five sensors, these results are a promising step towards wearable MEG that combines the advantages of MEG and EEG.

Authors

Institutions

Publication Details

Journal
Human Brain Mapping
Published
2025-09-27
DOI
https://doi.org/10.1002/hbm.70368
Primary Topic
Neuroscience and Music Perception
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Mismatch Negativity Compared: EEG, SQUID‐MEG, and Novel 4Helium‐OPMs

Julien Jung, Françoise Lecaignard, Jérémie Mattout, Sébastien Daligault et al.
Human Brain Mapping
Neuroscience and Music Perception
article

The Mismatch Negativity Compared: EEG, SQUID‐MEG, and Novel 4Helium‐OPMs

Julien Jung, Françoise Lecaignard, Jérémie Mattout, Sébastien Daligault, Tjerk P. Gutteling, Denis Schwartz, Étienne Labyt
article en

Abstract

Magneto-encephalography (MEG) provides a higher spatial resolution than electro-encephalography (EEG) to measure human auditory responses. However, conventional cryogenic MEG systems (SQUID-MEG) suffer from severe technological restrictions limiting, for instance, routine clinical use. Fortunately, a new generation of MEG sensors, optically pumped magnetometers (OPMs), has been developed to bridge the gap, combining the wearability of EEG with the benefits of MEG signal acquisition. We aim to assess their potential for studying auditory mismatch processing. The auditory mismatch negativity (MMN) is a well-characterized evoked component observable using a passive oddball paradigm with two-tone sound sequences. It has been extensively described using both EEG and MEG and is part of many EEG-based clinical applications, such as the assessment of patients with disorders of consciousness. MMN is therefore a relevant candidate to evaluate OPM performance. We use recently developed Helium-OPMs, which are high dynamic range MEG sensors that operate at room temperature. We compare their performance with cryogenic SQUID-MEG and EEG in a passive frequency oddball paradigm. Results show a significant MMN across subjects in all modalities as well as a high temporal similarity between modalities. Signal-to-noise ratios were also similar, and detection of significant individual MMN (within-subjects) using the OPM system was equal to or better than EEG. Given that the OPM system tested here is a prototype comprised of only five sensors, these results are a promising step towards wearable MEG that combines the advantages of MEG and EEG.

Human Brain MappingVol. 46(14)
Université Claude Bernard Lyon 1 (FR), Centre National de la Recherche Scientifique (FR), Inserm (FR), Laboratoire National des Champs Magnétiques Intenses (FR), Centre de Recherche en Neurosciences de Lyon (FR), Centre d'Exploration et de Recherche Médicale par Emission de Positons (FR)
Agence Nationale de la Recherche, Région Auvergne-Rhône-Alpes
Openalex Percentile: Top 74%
Neuroscience and Music Perception
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.