Self-Adaptive Polymer Fabry–Pérot Thermometer for High-Sensitivity and Wide-Linear-Range Sensing

Fiber-optic temperature sensors with advantages such as simplicity, low cost, and high sensitivity have attracted increasing attention. In this work, we propose a self-adaptive polymer Fabry-Pérot interferometer (PFPI) sensor for ultrasensitive and wide-linear-range thermal sensing. This design achieves a temperature sensitivity of 0.95 nm/°C, representing an enhancement of two orders of magnitude compared to conventional fiber Bragg gratings. To address the challenge of spectral shifts exceeding the free spectral range due to the high sensitivity, a local cross-correlation algorithm is introduced for accurate wavelength tracking. We demonstrate ultrahigh-resolution (0.025 °C) scanning thermal field imaging and sensitive human physiological monitoring, including precise body temperature and respiratory rate detection. These results highlight the dual capability of our PFPI sensor for both microscopic thermal mapping and non-invasive healthcare applications.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2025-09-12
DOI
https://doi.org/10.3390/bios15090602
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Self-Adaptive Polymer Fabry–Pérot Thermometer for High-Sensitivity and Wide-Linear-Range Sensing

Yifan Cheng, Maolin Yu, Junjie Liu, Jinhui Chen et al.
Biosensors
Advanced Fiber Optic Sensors
article

Self-Adaptive Polymer Fabry–Pérot Thermometer for High-Sensitivity and Wide-Linear-Range Sensing

Yifan Cheng, Maolin Yu, Junjie Liu, Jinhui Chen, Yingling Tan
article en

Abstract

Fiber-optic temperature sensors with advantages such as simplicity, low cost, and high sensitivity have attracted increasing attention. In this work, we propose a self-adaptive polymer Fabry-Pérot interferometer (PFPI) sensor for ultrasensitive and wide-linear-range thermal sensing. This design achieves a temperature sensitivity of 0.95 nm/°C, representing an enhancement of two orders of magnitude compared to conventional fiber Bragg gratings. To address the challenge of spectral shifts exceeding the free spectral range due to the high sensitivity, a local cross-correlation algorithm is introduced for accurate wavelength tracking. We demonstrate ultrahigh-resolution (0.025 °C) scanning thermal field imaging and sensitive human physiological monitoring, including precise body temperature and respiratory rate detection. These results highlight the dual capability of our PFPI sensor for both microscopic thermal mapping and non-invasive healthcare applications.

BiosensorsVol. 15(9)
Xiamen University (CN), Xiamen University of Technology (CN)
Openalex Percentile: Top 74%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.