<scp>LLZO</scp> ‐Assisted <scp>PEO</scp> ‐ <scp>PVDF</scp> Blend‐Based Polymer Electrolytes for Device Application

ABSTRACT This study uses a polymer blend as a host polymer prepared by PEO and PVDF‐HFP, with Li 7 La 3 Zr 2 O 12 (C‐LLZO) and Li 6.5 La 3 Zr 1.75 Te 0.25 O 12 (Te‐LLZO) as ceramic fillers and lithium trifluoro methane sulfonate (LiCF 3 SO 3 ) as a salt. Using the XRD and FTIR spectra, the impact of ceramic (C‐LLZO and Te‐LLZO) on enhancing the salt dissociation and cation coordination with oxygen atoms in PEO and fluorine atoms in PVDF‐HFP has been investigated. Notable changes in ceramic peak intensity, peak position, and the existence of an amorphous hump in XRD spectra indicate an increased amorphous content with low ceramic loading. However, the crystallinity of the electrolyte increases with increasing ceramic loading. With different ceramic loading, the vibrational bands of CF 2 and COC have shifted and varied. It shows that ceramic loading has significantly impacted cation coordination with those peaks. Conversely, the enhanced ion dissociation with ceramic variation is established by the deconvolution of FTIR in the wavenumber region of 1020–1050 cm −1 . The free anion content is substantial at 20 wt% ceramic loading, according to FTIR measurements. It suggests a greater likelihood of available cations for coordination. The optimized polymer blend‐salt‐ceramic composite sample shows an excellent DC conductivity at room temperature of 0.613 × 10 −3 Scm −1 . This is an enhancement of approximately two orders compared to the blend‐salt system. Along with that, this optimized polymer blend composite shows excellent voltage stability of 5.90 V and thermal stability up to ~400°C. Furthermore, an EDLC device has been developed using the optimized composite electrolyte. It shows an impressive specific capacitance of 6.52 mF/g at a 10 mV/s scan rate.

Authors

Institutions

Publication Details

Journal
Journal of Applied Polymer Science
Published
2025-09-26
DOI
https://doi.org/10.1002/app.58007
Citations
1
Primary Topic
Advanced Battery Materials and Technologies
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

LLZO ‐Assisted PEO ‐ PVDF Blend‐Based Polymer Electrolytes for Device Application

Avirup Das, Tausif Alam
1 citations
Journal of Applied Polymer Science
Advanced Battery Materials and Technologies
0.73
article

LLZO ‐Assisted PEO ‐ PVDF Blend‐Based Polymer Electrolytes for Device Application

Avirup Das, Tausif Alam
article en
1 citations

Abstract

ABSTRACT This study uses a polymer blend as a host polymer prepared by PEO and PVDF‐HFP, with Li 7 La 3 Zr 2 O 12 (C‐LLZO) and Li 6.5 La 3 Zr 1.75 Te 0.25 O 12 (Te‐LLZO) as ceramic fillers and lithium trifluoro methane sulfonate (LiCF 3 SO 3 ) as a salt. Using the XRD and FTIR spectra, the impact of ceramic (C‐LLZO and Te‐LLZO) on enhancing the salt dissociation and cation coordination with oxygen atoms in PEO and fluorine atoms in PVDF‐HFP has been investigated. Notable changes in ceramic peak intensity, peak position, and the existence of an amorphous hump in XRD spectra indicate an increased amorphous content with low ceramic loading. However, the crystallinity of the electrolyte increases with increasing ceramic loading. With different ceramic loading, the vibrational bands of CF 2 and COC have shifted and varied. It shows that ceramic loading has significantly impacted cation coordination with those peaks. Conversely, the enhanced ion dissociation with ceramic variation is established by the deconvolution of FTIR in the wavenumber region of 1020–1050 cm −1 . The free anion content is substantial at 20 wt% ceramic loading, according to FTIR measurements. It suggests a greater likelihood of available cations for coordination. The optimized polymer blend‐salt‐ceramic composite sample shows an excellent DC conductivity at room temperature of 0.613 × 10 −3 Scm −1 . This is an enhancement of approximately two orders compared to the blend‐salt system. Along with that, this optimized polymer blend composite shows excellent voltage stability of 5.90 V and thermal stability up to ~400°C. Furthermore, an EDLC device has been developed using the optimized composite electrolyte. It shows an impressive specific capacitance of 6.52 mF/g at a 10 mV/s scan rate.

Journal of Applied Polymer ScienceVol. 143(2)
Advanced Materials and Processes Research Institute (IN), Barkatullah University (IN)
Openalex Percentile: Top 23%
Advanced Battery Materials and Technologies
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.