Analysis and Optimization of Dynamic Characteristics of Primary Frequency Regulation Under Deep Peak Shaving Conditions for Industrial Steam Extraction Heating Thermal Power Units

This study investigates the primary frequency regulation dynamic characteristics of industrial steam extraction turbine units under deep peak regulation conditions. A high-fidelity integrated dynamic model was established, incorporating the governor system, steam turbine with extraction modules, and interconnected pipeline dynamics. Through comparative simulations and experimental validation, the model demonstrates high accuracy in replicating real-unit responses to frequency disturbances. For the power grid system in this study, the frequency disturbance mainly comes from three aspects: first, the power imbalance formed by the random mutation of the load side and the intermittence of new energy power generation; second, transformation of the energy structure directly reduces the available frequency modulation resources; third, the system-equivalent inertia collapse effect caused by the integration of high permeability new energy; the rotational inertia provided by the traditional synchronous unit is significantly reduced. In the cogeneration unit and its control system in Guangxi involved in this article, key findings reveal that increased peak regulation depth (30~50% rated power) exacerbates nonlinear fluctuations. This is due to boiler combustion stability thresholds and steam pressure variations. Key parameters—dead band, power limit, and droop coefficient—have coupled effects on performance. Specifically, too much dead band (>0.10 Hz) reduces sensitivity; likewise, too high a power limit (>4.44%) leads to overshoot and slow recovery. The robustness of parameter configurations is further validated under source-load random-intermittent coupling disturbances, highlighting enhanced anti-interference capability. By constructing a coordinated control model of primary frequency modulation, the regulation strategy of boiler and steam turbine linkage is studied, and the optimization interval of frequency modulation dead zone, adjustment coefficient, and frequency modulation limit parameters are quantified. Based on the sensitivity theory, the dynamic influence mechanism of the key control parameters in the main module is analyzed, and the degree of influence of each parameter on the frequency modulation performance is clarified. This research provides theoretical guidance for optimizing frequency regulation strategies in coal-fired units integrated with renewable energy systems.

Authors

Institutions

Publication Details

Journal
Processes
Published
2025-09-26
DOI
https://doi.org/10.3390/pr13103082
Primary Topic
Advanced Power Generation Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis and Optimization of Dynamic Characteristics of Primary Frequency Regulation Under Deep Peak Shaving Conditions for Industrial Steam Extraction Heating Thermal Power Units

Hong Sheng Hu, Zhiyuan Sun, Libin Wen, Jin Xi
Processes
Advanced Power Generation Technologies
article

Analysis and Optimization of Dynamic Characteristics of Primary Frequency Regulation Under Deep Peak Shaving Conditions for Industrial Steam Extraction Heating Thermal Power Units

Hong Sheng Hu, Zhiyuan Sun, Libin Wen, Jin Xi
article en

Abstract

This study investigates the primary frequency regulation dynamic characteristics of industrial steam extraction turbine units under deep peak regulation conditions. A high-fidelity integrated dynamic model was established, incorporating the governor system, steam turbine with extraction modules, and interconnected pipeline dynamics. Through comparative simulations and experimental validation, the model demonstrates high accuracy in replicating real-unit responses to frequency disturbances. For the power grid system in this study, the frequency disturbance mainly comes from three aspects: first, the power imbalance formed by the random mutation of the load side and the intermittence of new energy power generation; second, transformation of the energy structure directly reduces the available frequency modulation resources; third, the system-equivalent inertia collapse effect caused by the integration of high permeability new energy; the rotational inertia provided by the traditional synchronous unit is significantly reduced. In the cogeneration unit and its control system in Guangxi involved in this article, key findings reveal that increased peak regulation depth (30~50% rated power) exacerbates nonlinear fluctuations. This is due to boiler combustion stability thresholds and steam pressure variations. Key parameters—dead band, power limit, and droop coefficient—have coupled effects on performance. Specifically, too much dead band (>0.10 Hz) reduces sensitivity; likewise, too high a power limit (>4.44%) leads to overshoot and slow recovery. The robustness of parameter configurations is further validated under source-load random-intermittent coupling disturbances, highlighting enhanced anti-interference capability. By constructing a coordinated control model of primary frequency modulation, the regulation strategy of boiler and steam turbine linkage is studied, and the optimization interval of frequency modulation dead zone, adjustment coefficient, and frequency modulation limit parameters are quantified. Based on the sensitivity theory, the dynamic influence mechanism of the key control parameters in the main module is analyzed, and the degree of influence of each parameter on the frequency modulation performance is clarified. This research provides theoretical guidance for optimizing frequency regulation strategies in coal-fired units integrated with renewable energy systems.

ProcessesVol. 13(10)
Electric Power Research Institute (US), Wuhan University (CN), Guangxi Center for Disease Prevention and Control (CN)
Openalex Percentile: Top 74%
Advanced Power Generation Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.