Counteracting the Aging Process of the Aircraft’s DC Power Grid in the Context of Shaping the Characteristics of the Power Source

This article presents a proprietary method for measuring and adjusting the position of DC generator brushes relative to the neutral zone. This method enables shaping the characteristics of the power sources of the aircraft’s DC power grids, which has a beneficial effect on counteracting the aging process. Using generators with varying operating times (flight hours), selected research results on the effect of the brush position angle α relative to the magnetically neutral zone on operating conditions are presented. In addition, examples of abnormal operation of the DC electrical network in transient states and their possible negative effects on the operation of the aircraft (A/C) power network are presented. Finally, research results are presented demonstrating the practical application of power source characteristic shaping to effectively counteract the aging process of aircraft DC power networks.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-09-26
DOI
https://doi.org/10.3390/en18195132
Primary Topic
Engineering Diagnostics and Reliability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Counteracting the Aging Process of the Aircraft’s DC Power Grid in the Context of Shaping the Characteristics of the Power Source

S. Michalak, Tomasz Gajewski, Tomasz Tokarski
Energies
Engineering Diagnostics and Reliability
article

Counteracting the Aging Process of the Aircraft’s DC Power Grid in the Context of Shaping the Characteristics of the Power Source

S. Michalak, Tomasz Gajewski, Tomasz Tokarski
article en

Abstract

This article presents a proprietary method for measuring and adjusting the position of DC generator brushes relative to the neutral zone. This method enables shaping the characteristics of the power sources of the aircraft’s DC power grids, which has a beneficial effect on counteracting the aging process. Using generators with varying operating times (flight hours), selected research results on the effect of the brush position angle α relative to the magnetically neutral zone on operating conditions are presented. In addition, examples of abnormal operation of the DC electrical network in transient states and their possible negative effects on the operation of the aircraft (A/C) power network are presented. Finally, research results are presented demonstrating the practical application of power source characteristic shaping to effectively counteract the aging process of aircraft DC power networks.

EnergiesVol. 18(19)
Instytut Techniczny Wojsk Lotniczych (PL)
Openalex Percentile: Top 70%
Engineering Diagnostics and Reliability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.