Effect of the umbilical cord length on mode of delivery and perinatal outcome

Background: The umbilical cord is a vital anatomical structure connecting the fetus to the placenta, and its length along with the presence of nuchal loops may influence labor progression and neonatal outcomes. This study aimed to evaluate the relationship between umbilical cord length and mode of delivery, duration of labor, neonatal APGAR scores, NICU admissions, and incidence of fetal distress. Methods: A prospective observational study was conducted at Al-Ameen medical college hospital from July 2023 to January 2025, involving 200 pregnant women. Umbilical cord length and the presence and number of nuchal loops were documented at delivery. Maternal and neonatal outcomes, including mode of delivery, labor duration, fetal distress, and neonatal parameters, were recorded and analysed statistically. Results: The mean umbilical cord length was 50.68±11.75 cm. Although the incidence of caesarean delivery was higher in both short and long cord groups, the difference was not statistically significant (p=0.217). Labor duration was significantly prolonged in cases with nuchal cord, particularly among primigravida (17.62±1.38 h vs. 11.95±1.49 h). Neonates with nuchal loops had lower APGAR scores at 1 and 5 minutes (p=0.003), and NICU admission rates were higher among those with multiple loops (p<0.001). Fetal distress increased significantly with number of nuchal loops (p<0.0001). Conclusions: Abnormal cord length and multiple nuchal loops are significantly associated with prolonged labor, fetal distress, increased incidence of instrumental delivery, caesarean section due to cephalopelvic disproportion due to deflexed head, low APGAR score, NICU admission. Patients with 2-3 loop of cord around the neck can have normal vaginal delivery. There is increasing rate of caesarean section due to ultrasound diagnosis of cord around the neck at term, because of obstetrician distress and patients request rather than obstetric indication.

Authors

Institutions

Publication Details

Journal
International Journal of Reproduction Contraception Obstetrics and Gynecology
Published
2025-09-26
DOI
https://doi.org/10.18203/2320-1770.ijrcog20253086
Primary Topic
Pregnancy and preeclampsia studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of the umbilical cord length on mode of delivery and perinatal outcome

Gowramba R Sajjan, Syeda Mahin Saidani, Mohammed Abdul Azeem
International Journal of Reproduction Contraception Obstetrics and Gynecology
Pregnancy and preeclampsia studies
article

Effect of the umbilical cord length on mode of delivery and perinatal outcome

Gowramba R Sajjan, Syeda Mahin Saidani, Mohammed Abdul Azeem
article en

Abstract

Background: The umbilical cord is a vital anatomical structure connecting the fetus to the placenta, and its length along with the presence of nuchal loops may influence labor progression and neonatal outcomes. This study aimed to evaluate the relationship between umbilical cord length and mode of delivery, duration of labor, neonatal APGAR scores, NICU admissions, and incidence of fetal distress. Methods: A prospective observational study was conducted at Al-Ameen medical college hospital from July 2023 to January 2025, involving 200 pregnant women. Umbilical cord length and the presence and number of nuchal loops were documented at delivery. Maternal and neonatal outcomes, including mode of delivery, labor duration, fetal distress, and neonatal parameters, were recorded and analysed statistically. Results: The mean umbilical cord length was 50.68±11.75 cm. Although the incidence of caesarean delivery was higher in both short and long cord groups, the difference was not statistically significant (p=0.217). Labor duration was significantly prolonged in cases with nuchal cord, particularly among primigravida (17.62±1.38 h vs. 11.95±1.49 h). Neonates with nuchal loops had lower APGAR scores at 1 and 5 minutes (p=0.003), and NICU admission rates were higher among those with multiple loops (p<0.001). Fetal distress increased significantly with number of nuchal loops (p<0.0001). Conclusions: Abnormal cord length and multiple nuchal loops are significantly associated with prolonged labor, fetal distress, increased incidence of instrumental delivery, caesarean section due to cephalopelvic disproportion due to deflexed head, low APGAR score, NICU admission. Patients with 2-3 loop of cord around the neck can have normal vaginal delivery. There is increasing rate of caesarean section due to ultrasound diagnosis of cord around the neck at term, because of obstetrician distress and patients request rather than obstetric indication.

International Journal of Reproduction Contraception Obstetrics and GynecologyVol. 14(10)
Central University of Karnataka (IN), Al-Ameen Medical College (IN)
Openalex Percentile: Top 67%
Pregnancy and preeclampsia studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.