HSPAN-GNN-based fault detection for power transmission lines

Abstract To supply uninterrupted electric power is extremely crucial for the economy and daily life. The traditional manual inspection method for power transmission line fault detection has many disadvantages. Although deep learning has been applied in power transmission line detection, existing schemes have deficiencies in complex environment with low-resolution images and small target. To solve this problem, this paper proposes a visual feature modeling method based on graph convolution and constructs a graph neural network model, HSPAN-GNN (High-priority Subsampling with SPD and Attention Normalization-Graph Neural Network), which combines graph convolution and convolution operations. We build a novel HSPAN-GNN model includes a high-degree priority subsampling module to balance computational efficiency, memory overhead, and accelerate inference. The proposed Space-to-Depth Convolution (SPD-Conv) solves the detection problems in small target and low-resolution scenarios, and the Normalization-based Attention Module (NAM) enhances the detection performance. Experiments have shown that the HSPAN-GNN model can achieve efficient and accurate target detection of transmission lines.

Authors

Institutions

Publication Details

Journal
EURASIP Journal on Advances in Signal Processing
Published
2025-09-26
DOI
https://doi.org/10.1186/s13634-025-01251-6
Citations
1
Primary Topic
Power Line Inspection Robots
Type
article
Field-Weighted Citation Impact
0.71

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

HSPAN-GNN-based fault detection for power transmission lines

Bing Tian, Liang Zhao, Huan Xu, Na Zhang et al.
1 citations
EURASIP Journal on Advances in Signal Processing
Power Line Inspection Robots
0.71
article

HSPAN-GNN-based fault detection for power transmission lines

Bing Tian, Liang Zhao, Huan Xu, Na Zhang, Jiguang Zhao, Ximing Zhang, Yupeng Wei, Zhiming Wang
article en
1 citations

Abstract

Abstract To supply uninterrupted electric power is extremely crucial for the economy and daily life. The traditional manual inspection method for power transmission line fault detection has many disadvantages. Although deep learning has been applied in power transmission line detection, existing schemes have deficiencies in complex environment with low-resolution images and small target. To solve this problem, this paper proposes a visual feature modeling method based on graph convolution and constructs a graph neural network model, HSPAN-GNN (High-priority Subsampling with SPD and Attention Normalization-Graph Neural Network), which combines graph convolution and convolution operations. We build a novel HSPAN-GNN model includes a high-degree priority subsampling module to balance computational efficiency, memory overhead, and accelerate inference. The proposed Space-to-Depth Convolution (SPD-Conv) solves the detection problems in small target and low-resolution scenarios, and the Normalization-based Attention Module (NAM) enhances the detection performance. Experiments have shown that the HSPAN-GNN model can achieve efficient and accurate target detection of transmission lines.

EURASIP Journal on Advances in Signal ProcessingVol. 2025(1)
China Southern Power Grid (China) (CN)
Strong, National Key Research and Development Program of China
Openalex Percentile: Top 27%
Power Line Inspection Robots
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.