Assessment of Biocontainment Efficacy and Flow Cytometric Impact of a Novel Platform in High Containment Laboratories

Introduction: Flow cytometry remains one of the most central technologies with broad applications in immunology and infectious disease research. In the lack of compatible measures for pathogen inactivation, cytometric analysis of live cells derived from infectious samples classically poses exposure risks to both operators and environment. Enclosing a cell analyzer in a biosafety cabinet (BSC) could significantly improve safety margins for laboratory operations but has unknown impacts on instrument performance. Here, we describe and characterize the performance of a novel, BSC-housed analyzer for cytometric analysis of infectious samples within a biosafety level-3 laboratory. Methods: We investigated internal BSC and ultraviolet (UV) laser temperature over time. System stability was assessed using quality control particles with the BSC on and off. Aerosol generation was tested at four locations in normal and simulated failure modes using fluorescent Dragon Green beads. Results: Under these conditions, the temperature of the BSC and UV laser was stable during operations. The BSC did not significantly impact instrument performance or stability. Low amounts of aerosols were detected from vulnerable points in the system, and 15-fold reduction in aerosol generation was achieved with the introduction of a plate seal. Conclusions: Utilizing a tailored platform for cell analysis in high-containment laboratory, we demonstrate that BSC enclosure of the analyzer preserved operational performance of both units. Aerosol measurement studies revealed the importance of a BSC-contained instrument when investigating infectious samples. Our findings stress the need to accelerate efforts toward the integration of cytometry-based technologies in high-containment laboratories.

Authors

Institutions

Publication Details

Journal
Applied Biosafety
Published
2025-09-26
DOI
https://doi.org/10.1177/15356760251378149
Primary Topic
Biomedical and Engineering Education
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of Biocontainment Efficacy and Flow Cytometric Impact of a Novel Platform in High Containment Laboratories

Melanie Cohen, Iyadh Douagi, Julie Laux
Applied Biosafety
Biomedical and Engineering Education
article

Assessment of Biocontainment Efficacy and Flow Cytometric Impact of a Novel Platform in High Containment Laboratories

Melanie Cohen, Iyadh Douagi, Julie Laux
article en

Abstract

Introduction: Flow cytometry remains one of the most central technologies with broad applications in immunology and infectious disease research. In the lack of compatible measures for pathogen inactivation, cytometric analysis of live cells derived from infectious samples classically poses exposure risks to both operators and environment. Enclosing a cell analyzer in a biosafety cabinet (BSC) could significantly improve safety margins for laboratory operations but has unknown impacts on instrument performance. Here, we describe and characterize the performance of a novel, BSC-housed analyzer for cytometric analysis of infectious samples within a biosafety level-3 laboratory. Methods: We investigated internal BSC and ultraviolet (UV) laser temperature over time. System stability was assessed using quality control particles with the BSC on and off. Aerosol generation was tested at four locations in normal and simulated failure modes using fluorescent Dragon Green beads. Results: Under these conditions, the temperature of the BSC and UV laser was stable during operations. The BSC did not significantly impact instrument performance or stability. Low amounts of aerosols were detected from vulnerable points in the system, and 15-fold reduction in aerosol generation was achieved with the introduction of a plate seal. Conclusions: Utilizing a tailored platform for cell analysis in high-containment laboratory, we demonstrate that BSC enclosure of the analyzer preserved operational performance of both units. Aerosol measurement studies revealed the importance of a BSC-contained instrument when investigating infectious samples. Our findings stress the need to accelerate efforts toward the integration of cytometry-based technologies in high-containment laboratories.

Applied Biosafety
National Institutes of Health (US), National Institute of Allergy and Infectious Diseases (US)
Openalex Percentile: Top 75%
Biomedical and Engineering Education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.