Delayed-onset deep mesh infection presenting as discharging sinuses years after lichtenstein hernioplasty: a case report

Lichtenstein tension-free mesh hernioplasty is the gold standard for inguinal hernia repair due to low recurrence and minimal complications. However, delayed-onset mesh infections are rare and often underdiagnosed due to their subtle clinical presentation. They can manifest years later as chronic discharging sinuses and require high clinical suspicion for accurate diagnosis. Here a 50-year-old male presented with multiple discharging sinuses over the right inguinal region, several years after undergoing mesh hernioplasty. He was afebrile and hemodynamically stable. Magnetic resonance imaging (MRI) revealed subcutaneous T2 hyperintense collections, sinus tracts, and an enlarged lymph node. Surgery revealed purulent discharge with fibrotic adhesions and sinus tracts involving the mesh and spermatic cord, which were excised en bloc along with a lymph node. Histopathological analysis revealed foreign body-type granulomas, lymphocytic infiltration, and follicular hyperplasia, consistent with a chronic foreign body reaction. The patient received culture-sensitive antibiotics postoperatively and had an uneventful recovery with no recurrence on follow-up. Delayed-onset mesh infections are typically caused by biofilm-forming bacteria and may not respond to conservative treatment. Imaging assists in localization, but surgical removal of the infected mesh and affected tissues is the cornerstone of management. Histopathology helps confirm the chronic inflammatory response to synthetic mesh. This case emphasizes the need for long-term vigilance following mesh repair surgeries. Early recognition, thorough imaging, and prompt surgical intervention are vital for resolution. Awareness of this rare but significant complication can improve patient outcomes and reduce morbidity.

Authors

Institutions

Publication Details

Journal
International Surgery Journal
Published
2025-09-25
DOI
https://doi.org/10.18203/2349-2902.isj20253046
Primary Topic
Hernia repair and management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Delayed-onset deep mesh infection presenting as discharging sinuses years after lichtenstein hernioplasty: a case report

Som Raj Mahajan, Parineeta, Sachin Sharma
International Surgery Journal
Hernia repair and management
article

Delayed-onset deep mesh infection presenting as discharging sinuses years after lichtenstein hernioplasty: a case report

Som Raj Mahajan, Parineeta, Sachin Sharma
article en

Abstract

Lichtenstein tension-free mesh hernioplasty is the gold standard for inguinal hernia repair due to low recurrence and minimal complications. However, delayed-onset mesh infections are rare and often underdiagnosed due to their subtle clinical presentation. They can manifest years later as chronic discharging sinuses and require high clinical suspicion for accurate diagnosis. Here a 50-year-old male presented with multiple discharging sinuses over the right inguinal region, several years after undergoing mesh hernioplasty. He was afebrile and hemodynamically stable. Magnetic resonance imaging (MRI) revealed subcutaneous T2 hyperintense collections, sinus tracts, and an enlarged lymph node. Surgery revealed purulent discharge with fibrotic adhesions and sinus tracts involving the mesh and spermatic cord, which were excised en bloc along with a lymph node. Histopathological analysis revealed foreign body-type granulomas, lymphocytic infiltration, and follicular hyperplasia, consistent with a chronic foreign body reaction. The patient received culture-sensitive antibiotics postoperatively and had an uneventful recovery with no recurrence on follow-up. Delayed-onset mesh infections are typically caused by biofilm-forming bacteria and may not respond to conservative treatment. Imaging assists in localization, but surgical removal of the infected mesh and affected tissues is the cornerstone of management. Histopathology helps confirm the chronic inflammatory response to synthetic mesh. This case emphasizes the need for long-term vigilance following mesh repair surgeries. Early recognition, thorough imaging, and prompt surgical intervention are vital for resolution. Awareness of this rare but significant complication can improve patient outcomes and reduce morbidity.

International Surgery JournalVol. 12(10)
Dr. Rajendra Prasad Government Medical College (IN)
Openalex Percentile: Top 58%
Hernia repair and management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Delayed-onset deep mesh infection presenting as discharging sinuses years after lichtenstein hernioplasty: a case report — Som Raj Mahajan, Parineeta, et al. · International Surgery Journal (2025) | TGRS Research Map | TGRS