Quantification and Method Validation of Enalapril Maleate by Using Rp-Hplc

A rapid, economical, and highly accurate RP-HPLC method was established for the determination of enalapril maleate in both bulk drug and pharmaceutical formulations. Analysis was carried out using a Waters system equipped with an INTERSIL C-18 ODS column (250 × 4.6 mm, 5 μm particle size). The mobile phase consisted of acetonitrile and water in an 80:20 ratio, delivered at a flow rate of 1 ml/min, with detection at 208 nm. The retention time was observed at 3.2 minutes. The method exhibited linearity in the concentration range of 20–120 μg/ml, with a correlation coefficient of 0.9994. Sensitivity was high, with a limit of detection (LOD) of 0.1 μg/ml and a limit of quantification (LOQ) of 0.3 μg/ml. Validation followed International Conference on Harmonization (ICH) guidelines, and the method proved effective for the quantification of marketed formulations.

Authors

Publication Details

Journal
Journal of Pharmaceutical Quality Assurance and Quality Control
Published
2025-01-01
DOI
https://doi.org/10.46610/jqaqc.2025.v07i02.004
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantification and Method Validation of Enalapril Maleate by Using Rp-Hplc

Nagarajan Kandasamy, Vinay, Snigdha Bhardwaj
Journal of Pharmaceutical Quality Assurance and Quality Control
Analytical Methods in Pharmaceuticals
article

Quantification and Method Validation of Enalapril Maleate by Using Rp-Hplc

Nagarajan Kandasamy, Vinay, Snigdha Bhardwaj
article en

Abstract

A rapid, economical, and highly accurate RP-HPLC method was established for the determination of enalapril maleate in both bulk drug and pharmaceutical formulations. Analysis was carried out using a Waters system equipped with an INTERSIL C-18 ODS column (250 × 4.6 mm, 5 μm particle size). The mobile phase consisted of acetonitrile and water in an 80:20 ratio, delivered at a flow rate of 1 ml/min, with detection at 208 nm. The retention time was observed at 3.2 minutes. The method exhibited linearity in the concentration range of 20–120 μg/ml, with a correlation coefficient of 0.9994. Sensitivity was high, with a limit of detection (LOD) of 0.1 μg/ml and a limit of quantification (LOQ) of 0.3 μg/ml. Validation followed International Conference on Harmonization (ICH) guidelines, and the method proved effective for the quantification of marketed formulations.

Journal of Pharmaceutical Quality Assurance and Quality ControlVol. 7(2)
Openalex Percentile: Top 70%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.