Engineering Lanthanide Ion-Labeled Aptamers for ICP-MS Profiling of Serum-Derived Extracellular Vesicles from Colorectal Cancer

Membrane proteins on extracellular vesicles (EVs) derived from clinical serum samples have emerged as promising biomarkers for cancer screening, early diagnosis and prognosis. However, high-throughput profiling of multiple EV proteins with high sensitivity and high selectivity is challenge for clinical applications. In this work, we synthesized a polymer capable of chelating a set of lanthanide ions labeled at the terminal of DNA aptamers. These lanthanide ions-labeled aptamers have high affinity for specific EV proteins. By utilizing ICP-MS, multiplex profiling was performed for four specific proteins on the surface of EVs with high sensitivity and selectivity for CRC diagnosis. Precise diagnosis of EVs from CRC patients were achieved with an accuracy of 89.9%, sensitivity of 86.3%, and specificity of 100%. This method features high sensitivity, low background, and rapid detection, demonstrating potential clinical application for in vitro diagnosis with blood samples.

Authors

Institutions

Publication Details

Journal
JACS Au
Published
2025-09-25
DOI
https://doi.org/10.1021/jacsau.5c00641
Citations
1
Primary Topic
Extracellular vesicles in disease
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Engineering Lanthanide Ion-Labeled Aptamers for ICP-MS Profiling of Serum-Derived Extracellular Vesicles from Colorectal Cancer

Wang Xie, Ziyan Du, Ruizi Peng, Weihong Tan et al.
1 citations
JACS Au
Extracellular vesicles in disease
0.81
article

Engineering Lanthanide Ion-Labeled Aptamers for ICP-MS Profiling of Serum-Derived Extracellular Vesicles from Colorectal Cancer

Wang Xie, Ziyan Du, Ruizi Peng, Weihong Tan, Xiaobo Yu, Yawei Feng, Xiaoling Zheng, Hubin Chen, Yunshan Yang, Cong Luo, Y. Yang, Jiaxuan He, Zhiguang Zhou
article en
1 citations

Abstract

Membrane proteins on extracellular vesicles (EVs) derived from clinical serum samples have emerged as promising biomarkers for cancer screening, early diagnosis and prognosis. However, high-throughput profiling of multiple EV proteins with high sensitivity and high selectivity is challenge for clinical applications. In this work, we synthesized a polymer capable of chelating a set of lanthanide ions labeled at the terminal of DNA aptamers. These lanthanide ions-labeled aptamers have high affinity for specific EV proteins. By utilizing ICP-MS, multiplex profiling was performed for four specific proteins on the surface of EVs with high sensitivity and selectivity for CRC diagnosis. Precise diagnosis of EVs from CRC patients were achieved with an accuracy of 89.9%, sensitivity of 86.3%, and specificity of 100%. This method features high sensitivity, low background, and rapid detection, demonstrating potential clinical application for in vitro diagnosis with blood samples.

JACS AuVol. 5(10)
Shanghai Jiao Tong University (CN), Chinese Academy of Sciences (CN), Renji Hospital (CN), Zhejiang Cancer Hospital (CN), Institute of Molecular Medicine (IN), Beijing Proteome Research Center (CN), Shaoxing People's Hospital (CN), Zhejiang University of Technology (CN)
Openalex Percentile: Top 23%
Extracellular vesicles in disease
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.