Sensitivity Improvement via Differential Detection for Frequency-Locking Diamond Magnetometers

The magnetic resonance frequency-locking technique is recognized as an effective approach for simultaneously improving the dynamic range, performance stability, and measurement precision of diamond nitrogen vacancy (NV)-center magnetometers. Nevertheless, insufficient research on sensitivity limits the overall performance of frequency-locking diamond magnetometers. In this paper, we propose a dual-magnetic-resonance-frequency-locking (MRFL) differential detection method. Theoretical and experimental results demonstrate that the scaling factor between the sensor output and the magnetic field is doubled compared with that under the single-MRFL method, and the proposed method also enables alternating current (AC) magnetic field detection. The proposed system exhibits a measurement range from -0.29 mT to 0.30 mT. Furthermore, a sensitivity of 0.56 nT/√Hz is achieved, representing a 58.2% improvement relative to that of the single-MRFL method. Our work provides a viable solution for accelerating the transition of frequency-locking diamond magnetometers from laboratory research to practical applications.

Authors

Institutions

Publication Details

Journal
Micromachines
Published
2025-09-26
DOI
https://doi.org/10.3390/mi16101095
Primary Topic
Magnetic Field Sensors Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensitivity Improvement via Differential Detection for Frequency-Locking Diamond Magnetometers

Jun Liu, Yingjie Yang, Jian Gao, Jun Tang et al.
Micromachines
Magnetic Field Sensors Techniques
article

Sensitivity Improvement via Differential Detection for Frequency-Locking Diamond Magnetometers

Jun Liu, Yingjie Yang, Jian Gao, Jun Tang, Huan Fei Wen, Hao Guo, Hui Wang, Zhonghao Li, Zongmin Ma, Doudou Zheng, Yang Li
article en

Abstract

The magnetic resonance frequency-locking technique is recognized as an effective approach for simultaneously improving the dynamic range, performance stability, and measurement precision of diamond nitrogen vacancy (NV)-center magnetometers. Nevertheless, insufficient research on sensitivity limits the overall performance of frequency-locking diamond magnetometers. In this paper, we propose a dual-magnetic-resonance-frequency-locking (MRFL) differential detection method. Theoretical and experimental results demonstrate that the scaling factor between the sensor output and the magnetic field is doubled compared with that under the single-MRFL method, and the proposed method also enables alternating current (AC) magnetic field detection. The proposed system exhibits a measurement range from -0.29 mT to 0.30 mT. Furthermore, a sensitivity of 0.56 nT/√Hz is achieved, representing a 58.2% improvement relative to that of the single-MRFL method. Our work provides a viable solution for accelerating the transition of frequency-locking diamond magnetometers from laboratory research to practical applications.

MicromachinesVol. 16(10)
North University of China (CN), Taiyuan Institute of Technology (CN)
Openalex Percentile: Top 74%
Magnetic Field Sensors Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Sensitivity Improvement via Differential Detection for Frequency-Locking Diamond Magnetometers — Jun Liu, Yingjie Yang, et al. · Micromachines (2025) | TGRS Research Map | TGRS