Dynamic Performance Analysis of Parallel Connected Self Excited Induction Generators for Remote Power Systems

This paper examines the dynamic performance of parallel-connected self-excited induction generators (SEIGs) in off-grid setups under different loading conditions. It uses d-q reference frame modeling with LU decomposition and Runge-Kutta methods to analyze system stability and load sharing. Under resistive loading, the 5.5 kW and 2.2 kW SEIGs maintain output voltages of 240 V and 230 V respectively, with proportional power sharing. For resistive-inductive loads, the 5.5 kW unit demonstrates superior voltage regulation due to higher reactive power capacity, while the 2.2 kW unit experiences increased current variations. With a 1000 W nonlinear load, the system achieves stable operation where the 5.5 kW and 2.2 kW SEIGs supply 800 W and 300 W respectively, maintaining voltage at 180 V. Experimental results confirm the effectiveness of parallel SEIG operation in remote power generation, highlighting voltage regulation and load-sharing in off-grid applications.

Authors

Institutions

Publication Details

Published
2025-06-18
DOI
https://doi.org/10.1109/gcon65540.2025.11173410
Primary Topic
Wind Turbine Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic Performance Analysis of Parallel Connected Self Excited Induction Generators for Remote Power Systems

Rinchin W. Mosobi, Mrinal Kanti Rajak, Rajen Pudur
Wind Turbine Control Systems
article

Dynamic Performance Analysis of Parallel Connected Self Excited Induction Generators for Remote Power Systems

Rinchin W. Mosobi, Mrinal Kanti Rajak, Rajen Pudur
article en

Abstract

This paper examines the dynamic performance of parallel-connected self-excited induction generators (SEIGs) in off-grid setups under different loading conditions. It uses d-q reference frame modeling with LU decomposition and Runge-Kutta methods to analyze system stability and load sharing. Under resistive loading, the 5.5 kW and 2.2 kW SEIGs maintain output voltages of 240 V and 230 V respectively, with proportional power sharing. For resistive-inductive loads, the 5.5 kW unit demonstrates superior voltage regulation due to higher reactive power capacity, while the 2.2 kW unit experiences increased current variations. With a 1000 W nonlinear load, the system achieves stable operation where the 5.5 kW and 2.2 kW SEIGs supply 800 W and 300 W respectively, maintaining voltage at 180 V. Experimental results confirm the effectiveness of parallel SEIG operation in remote power generation, highlighting voltage regulation and load-sharing in off-grid applications.

Rajiv Gandhi University (IN), National Institute of Technology Arunachal Pradesh (IN)
Openalex Percentile: Top 74%
Wind Turbine Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.