Temperature and Axial Strain High-Accuracy Measurement Based on Forward-Brillouin-Scattering Direct Detection Structure

In this study, a novel temperature and axial strain simultaneous measurement method based on forward-Brillouin-scattering (FBS) direct detection structure is proposed and verified by experiments. The sensing mechanism exploits acousto-optic interactions that generate transverse acoustic waves through torsional-radial acoustic modes, which exhibit strong FBS signals and narrow spectral linewidths. By using the distinct temperature and axial strain dependencies of the FBS resonance peaks, two such modes are selected from the spectrum to form a sensitivity matrix, enabling decoupled dual-parameter measurement. Comparative experiments demonstrate that the proposed direct-detection scheme achieves superior measurement accuracy over the conventional Sagnac loop (SL) configuration, alongside a significantly simplified optical architecture. Experimental results validate the high performance of the system, achieving measurement uncertainties as low as 0.11 °C in temperature and 11 με in axial strain, derived from frequency shifts of the selected torsional–radial acoustic modes. The FBS direct detection structure, designed for simultaneous measurement of temperature and axial strain, holds broad application prospects in fields such as mechanical engineering, aerospace engineering, civil engineering, and environmental monitoring.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3614899
Primary Topic
Advanced Measurement and Detection Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Temperature and Axial Strain High-Accuracy Measurement Based on Forward-Brillouin-Scattering Direct Detection Structure

Chongjun He, Yuangang Lu, Wujun Zhang, Nan Guo et al.
IEEE Transactions on Instrumentation and Measurement
Advanced Measurement and Detection Methods
article

Temperature and Axial Strain High-Accuracy Measurement Based on Forward-Brillouin-Scattering Direct Detection Structure

Chongjun He, Yuangang Lu, Wujun Zhang, Nan Guo, Yuqin Feng, Hongcheng Ni
article en

Abstract

In this study, a novel temperature and axial strain simultaneous measurement method based on forward-Brillouin-scattering (FBS) direct detection structure is proposed and verified by experiments. The sensing mechanism exploits acousto-optic interactions that generate transverse acoustic waves through torsional-radial acoustic modes, which exhibit strong FBS signals and narrow spectral linewidths. By using the distinct temperature and axial strain dependencies of the FBS resonance peaks, two such modes are selected from the spectrum to form a sensitivity matrix, enabling decoupled dual-parameter measurement. Comparative experiments demonstrate that the proposed direct-detection scheme achieves superior measurement accuracy over the conventional Sagnac loop (SL) configuration, alongside a significantly simplified optical architecture. Experimental results validate the high performance of the system, achieving measurement uncertainties as low as 0.11 °C in temperature and 11 με in axial strain, derived from frequency shifts of the selected torsional–radial acoustic modes. The FBS direct detection structure, designed for simultaneous measurement of temperature and axial strain, holds broad application prospects in fields such as mechanical engineering, aerospace engineering, civil engineering, and environmental monitoring.

IEEE Transactions on Instrumentation and Measurement
Ministry of Industry and Information Technology (CN), Nanjing University of Aeronautics and Astronautics (CN)
Openalex Percentile: Top 74%
Advanced Measurement and Detection Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Temperature and Axial Strain High-Accuracy Measurement Based on Forward-Brillouin-Scattering Direct Detection Structure — Chongjun He, Yuangang Lu, et al. · IEEE Transactions on Instrumentation and Measurement (2025) | TGRS Research Map | TGRS