Cyber-Resilient Fault Diagnosis in Transmission Lines: A Substitute for Distance Relays Under Cyber-Attacks

The integration of digital technologies in substations—particularly communication protocols such as IEC 61850—improves operational efficiency and interoperability. However, it also introduces cyber-vulnerabilities that threaten data integrity and undermine the reliability of critical protection devices, such as distance relays, which are essential for maintaining system stability. To address this challenge, this paper proposes a cyber-resilient protection scheme that activates in response to cyber-attacks. This scheme, which serves as a temporary substitute for distance relays until the cyber-threat is mitigated, safeguards system security and stability under cyber-attacks. The proposed protection scheme mimics the zone-based fault detection of distance relays but leverages traveling waves (TWs)—which are the natural signatures of real faults—along with dedicated hard-wired current measurements and a Random Forest (RF) classifier to identify faults in each zone. The RF classifier is trained on the attenuation patterns of TW frequency components as they propagate from fault locations to the line terminal. Since attenuation patterns depend on both frequency and travel distance, the RF classifier can accurately determine the fault zone by extracting frequency-related features from the first TW using a wavelet transform and analyzing its attenuation characteristics. Simulation studies conducted on the IEEE 39-bus system demonstrate that the RF classifier achieves 99.56% accuracy in fault zone classification, while the entire scheme operates with a computational inference time of 0.18 ms, satisfying the real-time constraints of digital protection systems. These results confirm the effectiveness of the proposed method in maintaining reliable line protection under cyber-threat conditions.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3614876
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cyber-Resilient Fault Diagnosis in Transmission Lines: A Substitute for Distance Relays Under Cyber-Attacks

Mohsen Ghafouri, J R Southgate, M. Nasir Uddin, Mohammadmahdi Asghari et al.
IEEE Transactions on Instrumentation and Measurement
Power Systems Fault Detection
article

Cyber-Resilient Fault Diagnosis in Transmission Lines: A Substitute for Distance Relays Under Cyber-Attacks

Mohsen Ghafouri, J R Southgate, M. Nasir Uddin, Mohammadmahdi Asghari, Amir Ameli, Ali Doostmohammadi
article en

Abstract

The integration of digital technologies in substations—particularly communication protocols such as IEC 61850—improves operational efficiency and interoperability. However, it also introduces cyber-vulnerabilities that threaten data integrity and undermine the reliability of critical protection devices, such as distance relays, which are essential for maintaining system stability. To address this challenge, this paper proposes a cyber-resilient protection scheme that activates in response to cyber-attacks. This scheme, which serves as a temporary substitute for distance relays until the cyber-threat is mitigated, safeguards system security and stability under cyber-attacks. The proposed protection scheme mimics the zone-based fault detection of distance relays but leverages traveling waves (TWs)—which are the natural signatures of real faults—along with dedicated hard-wired current measurements and a Random Forest (RF) classifier to identify faults in each zone. The RF classifier is trained on the attenuation patterns of TW frequency components as they propagate from fault locations to the line terminal. Since attenuation patterns depend on both frequency and travel distance, the RF classifier can accurately determine the fault zone by extracting frequency-related features from the first TW using a wavelet transform and analyzing its attenuation characteristics. Simulation studies conducted on the IEEE 39-bus system demonstrate that the RF classifier achieves 99.56% accuracy in fault zone classification, while the entire scheme operates with a computational inference time of 0.18 ms, satisfying the real-time constraints of digital protection systems. These results confirm the effectiveness of the proposed method in maintaining reliable line protection under cyber-threat conditions.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Concordia University (CA), Lakehead University (CA)
Openalex Percentile: Top 67%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.