Plethysmography by Fiber Bragg Gratings Embedded in Silicone Patches

In this paper, a plethysmography sensor, based on Fiber Bragg Grating (FBG), is proposed. The FBG has been embedded within a proper silicone soft patch to improve the sensitivity of the sensor to external force/pressure, allowing it to measure the plethysmographic waveform. Simulations on Comsol Multiphysics software have been conducted to analyze the sensitivity to the pressure exerted by the heart pulse wave on the plethysmographic sensor, and to design the shape of the patch. Experimental results show that the proposed simple, inexpensive, and minimally invasive sensor can measure the sphygmic wave with a clear distinction between the cardiac systole and diastole peaks, key data on the cardiovascular status of the patients. In addition, from the second derivative of the plethysmographic signal (SDPTG), it is possible to trace the accelerated plethysmography which waveform contains important information related to cardiovascular rigidity.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3614893
Citations
1
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Plethysmography by Fiber Bragg Gratings Embedded in Silicone Patches

Agostino Iadicicco, Mariaconsiglia Cuomo, Stefania Campopiano, Elena De Vita et al.
1 citations
IEEE Transactions on Instrumentation and Measurement
Advanced Fiber Optic Sensors
0.73
article

Plethysmography by Fiber Bragg Gratings Embedded in Silicone Patches

Agostino Iadicicco, Mariaconsiglia Cuomo, Stefania Campopiano, Elena De Vita, Vincenzo Romano Marrazzo, Giovanni Breglio
article en
1 citations

Abstract

In this paper, a plethysmography sensor, based on Fiber Bragg Grating (FBG), is proposed. The FBG has been embedded within a proper silicone soft patch to improve the sensitivity of the sensor to external force/pressure, allowing it to measure the plethysmographic waveform. Simulations on Comsol Multiphysics software have been conducted to analyze the sensitivity to the pressure exerted by the heart pulse wave on the plethysmographic sensor, and to design the shape of the patch. Experimental results show that the proposed simple, inexpensive, and minimally invasive sensor can measure the sphygmic wave with a clear distinction between the cardiac systole and diastole peaks, key data on the cardiovascular status of the patients. In addition, from the second derivative of the plethysmographic signal (SDPTG), it is possible to trace the accelerated plethysmography which waveform contains important information related to cardiovascular rigidity.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Parthenope University of Naples (IT), University of Naples Federico II (IT)
Openalex Percentile: Top 23%
Advanced Fiber Optic Sensors
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Plethysmography by Fiber Bragg Gratings Embedded in Silicone Patches — Agostino Iadicicco, Mariaconsiglia Cuomo, et al. · IEEE Transactions on Instrumentation and Measurement (2025) | TGRS Research Map | TGRS