Plasma parameters analysis in DC and RF magnetron sputtering using finite element method

Abstract A comprehensive comparison of results obtained by finite element modelling (FEM) and plasma diagnostics between direct current (d.c.) and radio frequency (RF) magnetron sputtering at a frequency of 13.56 MHz is presented. This research studies the influence of power in the range 20 W to 90 W at a constant argon gas pressure of 1 Pa. The maximum plasma density values are observed at 90 W in the d.c. mode, reaching 1.41 × 10 17 m −3 , and 1.95 × 10 16 m −3 in the RF mode, with results obtained within 1 μ s after ignition of the plasma. The results of the experiments showed that the plasma concentration at a distance of 23 mm from the cathode has maximum values; indicating that the electron and ion density values increase as the d.c. and RF magnetron sputtering power increases. This research aims to demonstrate the different charge density values obtained in RF and d.c. plasma with FEM to facilitate the prediction of the magnetron sputtering discharge parameters of the MatER PUCP laboratory. Given that at this moment suitable models for RF sputtering are rather scarce, the obtained plasma parameters from FEM will be compared to plasma parameters that were obtained experimentally.

Authors

Institutions

Publication Details

Journal
Physica Scripta
Published
2025-09-26
DOI
https://doi.org/10.1088/1402-4896/ae0c48
Citations
1
Primary Topic
Metal and Thin Film Mechanics
Type
article
Field-Weighted Citation Impact
0.86
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Plasma parameters analysis in DC and RF magnetron sputtering using finite element method

S. Ulrich, H. Torreblanca, N Z Calderon, Rolf Grieseler et al.
1 citations
Physica Scripta
Metal and Thin Film Mechanics
0.86
article

Plasma parameters analysis in DC and RF magnetron sputtering using finite element method

S. Ulrich, H. Torreblanca, N Z Calderon, Rolf Grieseler, Michael Stueber, Carlo Eduardo Becerra Ahumada, Jaime Jean Paul Carreño La Rosa
article en
1 citations

Abstract

Abstract A comprehensive comparison of results obtained by finite element modelling (FEM) and plasma diagnostics between direct current (d.c.) and radio frequency (RF) magnetron sputtering at a frequency of 13.56 MHz is presented. This research studies the influence of power in the range 20 W to 90 W at a constant argon gas pressure of 1 Pa. The maximum plasma density values are observed at 90 W in the d.c. mode, reaching 1.41 × 10 17 m −3 , and 1.95 × 10 16 m −3 in the RF mode, with results obtained within 1 μ s after ignition of the plasma. The results of the experiments showed that the plasma concentration at a distance of 23 mm from the cathode has maximum values; indicating that the electron and ion density values increase as the d.c. and RF magnetron sputtering power increases. This research aims to demonstrate the different charge density values obtained in RF and d.c. plasma with FEM to facilitate the prediction of the magnetron sputtering discharge parameters of the MatER PUCP laboratory. Given that at this moment suitable models for RF sputtering are rather scarce, the obtained plasma parameters from FEM will be compared to plasma parameters that were obtained experimentally.

Physica ScriptaVol. 100(10)
Karlsruhe Institute of Technology (DE), École Polytechnique Fédérale de Lausanne (CH), National University of Engineering (PE), Pontificia Universidad Católica del Perú (PE)
Openalex Percentile: Top 25%
Metal and Thin Film Mechanics
0.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.