A Retrospective Cohort Study Comparing Robot-Assisted and Conventional Fluoroscopy-Guided Pedicle Screw Placement

<b>Background/Objectives</b>: Pedicle screw placement is crucial for restoring stability. Emerging robot-assisted technologies may offer enhanced precision and reduced radiation exposure. This study aimed to compare the accuracy and clinical outcomes of robot-assisted versus conventional fluoroscopy-guided pedicle screw placements. <b>Methods</b>: This retrospective cohort study included 218 patients undergoing pedicle screw placement at a single spine center between 2019 and 2023. Of these, 105 patients underwent robot-assisted surgery using the Mazor X™ Stealth Edition (Medtronic, Minneapolis, MN, USA), and 113 underwent conventional fluoroscopy-guided surgery. The primary outcome was screw placement accuracy (Grade 0 = optimal, Grades 1-3 = suboptimal, according to the Gertzbein-Robbins classification). Secondary outcomes included estimated blood loss (EBL), radiation exposure, length of hospital stay (LOS), clinical outcome according to the Macnab classification, postoperative pain, and adverse events. <b>Results</b>: Robot-assisted surgery demonstrated significantly higher accuracy in screw placement, with 93.33% achieving Grade 0 accuracy versus 78.76% in the conventional group (<i>p</i> = 0.002). This corresponded to an odds ratio (OR) of 3.78 (95% CI: 1.55-9.19, <i>p</i> = 0.003). The number needed to treat (NNT) to achieve one additional optimal screw placement was 6.9. Robot-assisted surgery demonstrated significantly higher accuracy in screw placement. Moreover, robot-assisted procedures were associated with reduced estimated blood loss (EBL), shorter length of stay (LOS), and lower radiation exposure times; patient-reported outcomes (VAS and Macnab) were also improved (OR = 3.34, 95% CI: 1.89-5.91). Duration of surgery, adverse events, and revision rates were comparable between the two groups. <b>Conclusions</b>: This study supports the clinical benefits of robot-assisted pedicle screw placement, particularly in achieving higher accuracy and reducing EBL and LOS. Future research should explore long-term outcomes, cost-effectiveness, and the generalizability of these results to a broader patient population.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-09-26
DOI
https://doi.org/10.3390/jcm14196831
Citations
1
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Retrospective Cohort Study Comparing Robot-Assisted and Conventional Fluoroscopy-Guided Pedicle Screw Placement

Emanuele Maragno, Michael Schwake, Marco Gallus, Hany M.A. Seif et al.
1 citations
Journal of Clinical Medicine
Spinal Fractures and Fixation Techniques
2.01
article

A Retrospective Cohort Study Comparing Robot-Assisted and Conventional Fluoroscopy-Guided Pedicle Screw Placement

Emanuele Maragno, Michael Schwake, Marco Gallus, Hany M.A. Seif, Szabolcs Szeöke
article en
1 citations

Abstract

<b>Background/Objectives</b>: Pedicle screw placement is crucial for restoring stability. Emerging robot-assisted technologies may offer enhanced precision and reduced radiation exposure. This study aimed to compare the accuracy and clinical outcomes of robot-assisted versus conventional fluoroscopy-guided pedicle screw placements. <b>Methods</b>: This retrospective cohort study included 218 patients undergoing pedicle screw placement at a single spine center between 2019 and 2023. Of these, 105 patients underwent robot-assisted surgery using the Mazor X™ Stealth Edition (Medtronic, Minneapolis, MN, USA), and 113 underwent conventional fluoroscopy-guided surgery. The primary outcome was screw placement accuracy (Grade 0 = optimal, Grades 1-3 = suboptimal, according to the Gertzbein-Robbins classification). Secondary outcomes included estimated blood loss (EBL), radiation exposure, length of hospital stay (LOS), clinical outcome according to the Macnab classification, postoperative pain, and adverse events. <b>Results</b>: Robot-assisted surgery demonstrated significantly higher accuracy in screw placement, with 93.33% achieving Grade 0 accuracy versus 78.76% in the conventional group (<i>p</i> = 0.002). This corresponded to an odds ratio (OR) of 3.78 (95% CI: 1.55-9.19, <i>p</i> = 0.003). The number needed to treat (NNT) to achieve one additional optimal screw placement was 6.9. Robot-assisted surgery demonstrated significantly higher accuracy in screw placement. Moreover, robot-assisted procedures were associated with reduced estimated blood loss (EBL), shorter length of stay (LOS), and lower radiation exposure times; patient-reported outcomes (VAS and Macnab) were also improved (OR = 3.34, 95% CI: 1.89-5.91). Duration of surgery, adverse events, and revision rates were comparable between the two groups. <b>Conclusions</b>: This study supports the clinical benefits of robot-assisted pedicle screw placement, particularly in achieving higher accuracy and reducing EBL and LOS. Future research should explore long-term outcomes, cost-effectiveness, and the generalizability of these results to a broader patient population.

Journal of Clinical MedicineVol. 14(19)
Witten/Herdecke University (DE), University of California, San Francisco (US), University Hospital Münster (DE), Klinikum Dortmund (DE), Brüderkrankenhaus St. Josef Paderborn (DE)
Openalex Percentile: Top 11%
Spinal Fractures and Fixation Techniques
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.