Comparative Assessment of Seismic Damping Scheme for Multi-Storey Frame Structures

Traditional anti-seismic methods are constrained by high construction costs and the potential for severe structural damage under earthquakes. Energy dissipation technology provides an effective solution for structural earthquake resistance by incorporating energy-dissipating devices within structures to actively absorb seismic energy. However, existing research lacks in-depth analysis of the influence of energy dissipation devices’ placement on structural dynamic response. Therefore, this study investigates the seismic mitigation effectiveness of viscous dampers in multi-storey frame structures and their optimal placement strategies. A comprehensive parametric investigation was conducted using a representative three-storey steel-frame kindergarten facility in Shandong Province as the prototype structure. Advanced finite element modeling was implemented through ETABS software to establish a high-fidelity structural analysis framework. Based on the supplemental virtual damping ratio seismic design method, damping schemes were designed, and the influence patterns of different viscous damper arrangement schemes on the seismic mitigation effectiveness of multi-storey frame structures were systematically investigated. Through rigorous comparative assessment of dynamic response characteristics and energy dissipation mechanisms inherent to three distinct energy dissipation device deployment strategies (perimeter distribution, central concentration, and upper-storey localization), this investigation delineates the governing principles underlying spatial positioning effects on structural seismic mitigation performance. This comprehensive investigation elucidates several pivotal findings: damping schemes developed through the supplemental virtual damping ratio-based design methodology demonstrate excellent applicability and predictive accuracy. All three spatial configurations effectively attenuate structural seismic response, achieving storey shear reductions of 15–30% and inter-storey drift reductions of 19–28%. Damper spatial positioning critically influences mitigation performance, with perimeter distribution outperforming central concentration, while upper-storey localization exhibits optimal overall effectiveness. These findings validate the engineering viability and structural reliability of viscous dampers in multi-storey frame applications, establishing a robust scientific foundation for energy dissipation technology implementation in seismic design practice.

Authors

Publication Details

Journal
Infrastructures
Published
2025-09-26
DOI
https://doi.org/10.3390/infrastructures10100258
Citations
2
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
1.91

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Assessment of Seismic Damping Scheme for Multi-Storey Frame Structures

Pengfei Ma, Shuming Jia
2 citations
Infrastructures
Seismic Performance and Analysis
1.91
article

Comparative Assessment of Seismic Damping Scheme for Multi-Storey Frame Structures

Pengfei Ma, Shuming Jia
article en
2 citations

Abstract

Traditional anti-seismic methods are constrained by high construction costs and the potential for severe structural damage under earthquakes. Energy dissipation technology provides an effective solution for structural earthquake resistance by incorporating energy-dissipating devices within structures to actively absorb seismic energy. However, existing research lacks in-depth analysis of the influence of energy dissipation devices’ placement on structural dynamic response. Therefore, this study investigates the seismic mitigation effectiveness of viscous dampers in multi-storey frame structures and their optimal placement strategies. A comprehensive parametric investigation was conducted using a representative three-storey steel-frame kindergarten facility in Shandong Province as the prototype structure. Advanced finite element modeling was implemented through ETABS software to establish a high-fidelity structural analysis framework. Based on the supplemental virtual damping ratio seismic design method, damping schemes were designed, and the influence patterns of different viscous damper arrangement schemes on the seismic mitigation effectiveness of multi-storey frame structures were systematically investigated. Through rigorous comparative assessment of dynamic response characteristics and energy dissipation mechanisms inherent to three distinct energy dissipation device deployment strategies (perimeter distribution, central concentration, and upper-storey localization), this investigation delineates the governing principles underlying spatial positioning effects on structural seismic mitigation performance. This comprehensive investigation elucidates several pivotal findings: damping schemes developed through the supplemental virtual damping ratio-based design methodology demonstrate excellent applicability and predictive accuracy. All three spatial configurations effectively attenuate structural seismic response, achieving storey shear reductions of 15–30% and inter-storey drift reductions of 19–28%. Damper spatial positioning critically influences mitigation performance, with perimeter distribution outperforming central concentration, while upper-storey localization exhibits optimal overall effectiveness. These findings validate the engineering viability and structural reliability of viscous dampers in multi-storey frame applications, establishing a robust scientific foundation for energy dissipation technology implementation in seismic design practice.

InfrastructuresVol. 10(10)
Natural Science Foundation of Gansu Province
Openalex Percentile: Top 13%
Seismic Performance and Analysis
1.91
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.