A microneedle device for rapid dermal interstitial fluid sampling

Dermal interstitial fluid (ISF) offers a promising alternative to invasive blood tests and opportunities for skin diagnostics. Progress in both the understanding and adoption of ISF tests is hindered by sampling challenges, including lengthy collection times, non-negligible failure rates, variable collection volumes, and inconsistent bioanalyte levels. The causes of many of these issues are not well understood. We demonstrate a microneedle device that is several times faster than state of the art, collecting an average of 15.5 mg of ISF in 5 minutes in humans with near-zero failure rate. This improvement was achieved by designing the spatial pressure gradient driving ISF flow. The influence of penetration depth, collection time, pressure, and age on ISF collection was elucidated, with Darcy's law explaining multiple observations. A data-driven acceptance criterion of <1% blood contamination for ISF is proposed. The device and findings presented will empower researchers to better conduct robust studies in the development of ISF diagnostics.

Authors

Institutions

Publication Details

Journal
Science Advances
Published
2025-09-24
DOI
https://doi.org/10.1126/sciadv.adx5492
Citations
3
Primary Topic
Advancements in Transdermal Drug Delivery
Type
article
Field-Weighted Citation Impact
2.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A microneedle device for rapid dermal interstitial fluid sampling

Andy H. Hung, Dan Ilyin, Sharon J. Pitteri, Steven P. Poplack et al.
3 citations
Science Advances
Advancements in Transdermal Drug Delivery
2.37
article

A microneedle device for rapid dermal interstitial fluid sampling

Andy H. Hung, Dan Ilyin, Sharon J. Pitteri, Steven P. Poplack, Joseph M. DeSimone, Utkan Demirci, Fernando Jose Garcia-Marques, Yee Lin Tan, Prima Dewi Sinawang, Netra U. Rajesh, Abel Bermudez, Gunilla B. Jacobson, J. C. Hwang, Stephanie M. Boczek
article en
3 citations

Abstract

Dermal interstitial fluid (ISF) offers a promising alternative to invasive blood tests and opportunities for skin diagnostics. Progress in both the understanding and adoption of ISF tests is hindered by sampling challenges, including lengthy collection times, non-negligible failure rates, variable collection volumes, and inconsistent bioanalyte levels. The causes of many of these issues are not well understood. We demonstrate a microneedle device that is several times faster than state of the art, collecting an average of 15.5 mg of ISF in 5 minutes in humans with near-zero failure rate. This improvement was achieved by designing the spatial pressure gradient driving ISF flow. The influence of penetration depth, collection time, pressure, and age on ISF collection was elucidated, with Darcy's law explaining multiple observations. A data-driven acceptance criterion of <1% blood contamination for ISF is proposed. The device and findings presented will empower researchers to better conduct robust studies in the development of ISF diagnostics.

Science AdvancesVol. 11(39)
Stanford University (US)
Openalex Percentile: Top 10%
Advancements in Transdermal Drug Delivery
2.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.