Critical evaluation of the gran method for free acidity determination in sulfuric solutions containing interfering ions

The Gran method, developed in the mid-20th century, remains a widely used technique for potentiometric determination of equivalence points in acid–base titrations. This study critically evaluates its performance for determining free acidity in sulfuric acid liquors, particularly under interference from Fe³⁺, Fe²⁺, and Al³⁺ ions. Experimental results demonstrated that Fe³⁺ concentrations above 8 g L-1 cause endpoint distortion, limiting the method's applicability in complex leachates. For comparison, the oxalate method was also evaluated and exhibited superior applicability limits, since the method is susceptible to interferents in the presence of trivalent cations. While the Gran method retained high precision in strongly acidic solutions (>1 N H₂SO₄), its accuracy declined under low acidity or high Fe³⁺ levels. These findings support the continued use of the Gran method in hydrometallurgical processes, if sample composition is controlled and validated. Practical guidelines and comparative criteria are provided to assist in method selection for industrial monitoring.

Authors

Institutions

Publication Details

Journal
Brazilian Applied Science Review
Published
2025-09-23
DOI
https://doi.org/10.34115/basrv9n2-004
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Critical evaluation of the gran method for free acidity determination in sulfuric solutions containing interfering ions

J Santos, Antônio Clareti Pereira
Brazilian Applied Science Review
Analytical Chemistry and Sensors
article

Critical evaluation of the gran method for free acidity determination in sulfuric solutions containing interfering ions

J Santos, Antônio Clareti Pereira
article en

Abstract

The Gran method, developed in the mid-20th century, remains a widely used technique for potentiometric determination of equivalence points in acid–base titrations. This study critically evaluates its performance for determining free acidity in sulfuric acid liquors, particularly under interference from Fe³⁺, Fe²⁺, and Al³⁺ ions. Experimental results demonstrated that Fe³⁺ concentrations above 8 g L-1 cause endpoint distortion, limiting the method's applicability in complex leachates. For comparison, the oxalate method was also evaluated and exhibited superior applicability limits, since the method is susceptible to interferents in the presence of trivalent cations. While the Gran method retained high precision in strongly acidic solutions (>1 N H₂SO₄), its accuracy declined under low acidity or high Fe³⁺ levels. These findings support the continued use of the Gran method in hydrometallurgical processes, if sample composition is controlled and validated. Practical guidelines and comparative criteria are provided to assist in method selection for industrial monitoring.

Brazilian Applied Science ReviewVol. 9(2)
Universidade Presbiteriana Mackenzie (BR)
Openalex Percentile: Top 65%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.