Abstract Tracheal stenosis is a condition characterized by narrowing of the trachea due to congenital anomalies or prolonged intubation. It is conventionally treated with surgical procedures such as tracheal resection and reconstruction. These are associated with recurrence of stenosis, inflammation, and sepsis. There is a growing interest in developing minimally invasive techniques for reshaping tracheal cartilage. Electromechanical reshaping (EMR) has emerged as a promising approach, but the use of conventional flat and double-sided strip electrodes limits its safety and clinical applicability. The trachea presents a challenging scenario wherein noninvasive access is limited to the luminal side. We have designed a novel single-sided strip electrode configuration which can be applied on the luminal side of the trachea. Using ex vivo goat tracheal cartilages, we optimized the dosimetry for efficient shape retention. Live-dead imaging to analyze the cell death, dimethyl methylene blue (DMMB) assay to assess the release of sulfated glycosaminoglycans (sGAG), attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy to assess the molecular changes in the reshaped trachea and histopathology to assess the tissue integrity after reshaping confirmed minimal tissue damage and effective shape retention with the single-sided strip electrode. The single-sided strip electrode was tested on a whole ex vivo goat trachea, and the results demonstrated a significant increase in tracheal airway diameter, highlighting its effectiveness and practical applicability. These findings suggest that the single-sided strip electrode configuration provides a minimally invasive and effective method for reshaping tracheal cartilage, presenting a promising alternative for treating tracheal stenosis.

Authors

Institutions

Publication Details

Journal
Journal of Medical Devices
Published
2025-09-26
DOI
https://doi.org/10.1115/1.4069908
Primary Topic
Tracheal and airway disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Endotracheal Tube-Based Electrode for Noninvasive Treatment of Tracheal Stenosis

Gowri Manohari Balachander, Mohamed Jameer Basha Jahankir, H. Ramesh
Journal of Medical Devices
Tracheal and airway disorders
article

A Novel Endotracheal Tube-Based Electrode for Noninvasive Treatment of Tracheal Stenosis

Gowri Manohari Balachander, Mohamed Jameer Basha Jahankir, H. Ramesh
article en

Abstract

Abstract Tracheal stenosis is a condition characterized by narrowing of the trachea due to congenital anomalies or prolonged intubation. It is conventionally treated with surgical procedures such as tracheal resection and reconstruction. These are associated with recurrence of stenosis, inflammation, and sepsis. There is a growing interest in developing minimally invasive techniques for reshaping tracheal cartilage. Electromechanical reshaping (EMR) has emerged as a promising approach, but the use of conventional flat and double-sided strip electrodes limits its safety and clinical applicability. The trachea presents a challenging scenario wherein noninvasive access is limited to the luminal side. We have designed a novel single-sided strip electrode configuration which can be applied on the luminal side of the trachea. Using ex vivo goat tracheal cartilages, we optimized the dosimetry for efficient shape retention. Live-dead imaging to analyze the cell death, dimethyl methylene blue (DMMB) assay to assess the release of sulfated glycosaminoglycans (sGAG), attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy to assess the molecular changes in the reshaped trachea and histopathology to assess the tissue integrity after reshaping confirmed minimal tissue damage and effective shape retention with the single-sided strip electrode. The single-sided strip electrode was tested on a whole ex vivo goat trachea, and the results demonstrated a significant increase in tracheal airway diameter, highlighting its effectiveness and practical applicability. These findings suggest that the single-sided strip electrode configuration provides a minimally invasive and effective method for reshaping tracheal cartilage, presenting a promising alternative for treating tracheal stenosis.

Journal of Medical DevicesVol. 20(1)
Technologies pour la Santé (FR), Indian Institute of Technology BHU (IN), Banaras Hindu University (IN)
Openalex Percentile: Top 62%
Tracheal and airway disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.