A Novel Bioaerosol Chamber to Measure the Inactivation Rate of Airborne Viruses at Low Far-UV-C Radiation Doses

Abstract 222 nm Far-UV-C light is considered an effective technology to inactivate airborne viruses in indoor environments, even while being occupied by humans. This is due to the safer characteristics of 222 nm UV-C light, which has much higher exposure limits as compared to the more traditional 254 nm UV-C. Several studies have reported on the susceptibility of viruses in laboratory aerosol chambers. Unfortunately, the chambers used in these studies have complex air-flow characteristics and non-uniform UV irradiance, resulting in a large variability in the calculated dose of the UV. In this study, we report the design and construction of a novel UV-C exposure chamber, with a well-defined laminar flow profile and nearly uniform UV-C irradiance across the aerosol path. This was done by using pairs of UV-C lamps on both sides of the virus aerosol flow. The new Far-UV-C exposure chamber provides a simpler UV dose calculation with less variability, resulting in more accurate virus inactivation rate measurements. We demonstrated the use of the new chamber for the inactivation of HCoV-OC43 betacoronavirus (a surrogate for SARS-CoV-2) at low Far-UV-C doses. We found an HCoV-OC43 virus inactivation rate of 6.51 ± 1.69 cm 2 mJ −1 (95% CI), that can be used for designing Far-UV-C disinfection systems for continuous operation at low doses of 222 nm UV-C light. We have also measured the ozone generation rate for the lamps used in our new exposure chamber; we conclude that these lamps can be safely used with minimum ozone generation (49.9 ± 9.8 µg h −1 ) in indoor environments. Graphical abstract

Authors

Institutions

Publication Details

Journal
Aerosol and Air Quality Research
Published
2025-09-26
DOI
https://doi.org/10.1007/s44408-025-00052-8
Citations
1
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
1.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Bioaerosol Chamber to Measure the Inactivation Rate of Airborne Viruses at Low Far-UV-C Radiation Doses

Francisco J. Romay, Alvin C.K. Lai, Aaron M. Collins, Nader M. Sobhy et al.
1 citations
Aerosol and Air Quality Research
Infection Control and Ventilation
1.52
article

A Novel Bioaerosol Chamber to Measure the Inactivation Rate of Airborne Viruses at Low Far-UV-C Radiation Doses

Francisco J. Romay, Alvin C.K. Lai, Aaron M. Collins, Nader M. Sobhy, Sagar M. Goyal, Minghao Wang, Christiana Rezk Bottros Youssef, David Y.H. Pui, Ryne A. Juidici
article en
1 citations

Abstract

Abstract 222 nm Far-UV-C light is considered an effective technology to inactivate airborne viruses in indoor environments, even while being occupied by humans. This is due to the safer characteristics of 222 nm UV-C light, which has much higher exposure limits as compared to the more traditional 254 nm UV-C. Several studies have reported on the susceptibility of viruses in laboratory aerosol chambers. Unfortunately, the chambers used in these studies have complex air-flow characteristics and non-uniform UV irradiance, resulting in a large variability in the calculated dose of the UV. In this study, we report the design and construction of a novel UV-C exposure chamber, with a well-defined laminar flow profile and nearly uniform UV-C irradiance across the aerosol path. This was done by using pairs of UV-C lamps on both sides of the virus aerosol flow. The new Far-UV-C exposure chamber provides a simpler UV dose calculation with less variability, resulting in more accurate virus inactivation rate measurements. We demonstrated the use of the new chamber for the inactivation of HCoV-OC43 betacoronavirus (a surrogate for SARS-CoV-2) at low Far-UV-C doses. We found an HCoV-OC43 virus inactivation rate of 6.51 ± 1.69 cm 2 mJ −1 (95% CI), that can be used for designing Far-UV-C disinfection systems for continuous operation at low doses of 222 nm UV-C light. We have also measured the ozone generation rate for the lamps used in our new exposure chamber; we conclude that these lamps can be safely used with minimum ozone generation (49.9 ± 9.8 µg h −1 ) in indoor environments. Graphical abstract

Aerosol and Air Quality ResearchVol. 25(10)
University of Minnesota (US), City University of Hong Kong (HK), Zagazig University (EG), Open Society (CZ)
U.S. Department of Agriculture, 3M, Donaldson Company, LG Electronics, Samsung, National Institute of Food and Agriculture, National Institute for Occupational Safety and Health
Openalex Percentile: Top 14%
Infection Control and Ventilation
1.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.