Infrared (IR) Shading as a Strategy to Mitigate Overheating in Traditional Buildings
In urban heat islands with sun-exposed roofs, the cooling potential of unfinished attics is often insufficient. Attics and the adjacent floor often overheat and do not cool sufficiently during tropical nights. Because of heritage-preservation requirements and limited structural reserve in historic roof constructions, it is often not possible to install heat-dissipating photovoltaic modules or add a superimposed cold-roof assembly above the existing roof skin. A possible solution is ‘infrared (IR) shading’, which uses interior IR-shading elements to shield long-wave radiation from the solar-heated roof skin. The research had two goals: (i) develop and evaluate lightweight IR-shading elements that can be reversibly mounted at rafter level on the attic side; and (ii) investigate how rafter-field ventilation can remove heat from the IR-shading elements.
Authors
- Günther Kain (ORCID: https://orcid.org/0000-0001-5367-2730)
- Friedrich Idam (ORCID: https://orcid.org/0009-0002-3344-6503)
Institutions
- Fachhochschule Salzburg (AT)
- Technická univerzita vo Zvolene (SK)
- Oldham Council (GB)
Publication Details
- Journal
- Buildings
- Published
- 2025-09-25
- DOI
- https://doi.org/10.3390/buildings15193471
- Citations
- 1
- Primary Topic
- Building Energy and Comfort Optimization
- Type
- article
- Field-Weighted Citation Impact
- 1.01