A Tick of the Clock: Finding the Sweet Spot in Tilt Table Test. The Effectiveness of Short‐Duration Head‐Up Tilt Test as a Diagnostic Tool in Suspected Vasovagal Patients: A Retrospective Observational Study in a Tertiary Syncope Unit
The 15-min HUTT protocol has similar results to the 20-min protocol. Saving 10 min for each test has several potential benefits, such as increasing patient acceptance, decreasing patient discomfort, and enabling the conduct of more tests in a day in a syncope unit.
Authors
- Parichehr Ghahari (ORCID: https://orcid.org/0009-0005-6434-0148)
- Parvin Kalhor (ORCID: https://orcid.org/0009-0003-4511-7659)
- Nasrin Asgari (ORCID: https://orcid.org/0000-0001-8551-0947)
- Arash Jalali (ORCID: https://orcid.org/0000-0003-3225-8498)
- Saeed Sadeghian
Institutions
- Tehran University of Medical Sciences (IR)
Publication Details
- Journal
- Journal of Arrhythmia
- Published
- 2025-09-25
- DOI
- https://doi.org/10.1002/joa3.70190
- Primary Topic
- Cardiovascular Syncope and Autonomic Disorders
- Type
- article
- Field-Weighted Citation Impact
- 0.00