A hybrid planning framework for virtual capacity-enhanced distribution transformer considering time-division multiplexing of energy storage unit

• A concept about virtual capacity-enhanced distribution transformer is proposed. • A hybrid planning framework is developed to determine the most economical and technically effective capacity-enhanced scheme. • A time-division multiplexing strategy is introduced to improve utilization of energy storage unit. • The peak-valley disparities and the “duck curve” phenomenon are addressed using the proposed method. Conventional (distribution transformers) DT capacity enhancement through replacement with larger units often incurs high investment costs and suboptimal asset utilization. To address these issues, this paper proposes a virtual capacity-enhanced scheme for DTs based on battery (energy storage unit) ESUs. A TDM strategy is introduced to improve ESU operation efficiency, and an optimal configuration model for ESU capacity is proposed to balance economic benefits and operational performance. A hybrid capacity-enhanced decision-making framework is further developed to guide DT capacity enhancement decisions by systematically evaluating virtual, conventional, and combined strategies. Case studies show that the virtual capacity-enhanced DT performs better under low overload conditions. Compared with traditional and purely virtual schemes, the hybrid scheme reduces five-year cumulative costs by 14.18 % and 11.61 %, respectively. In addition, the proposed TDM strategy increases the annual cumulative discharge duration of the ESU by 1233 h, and reduces the average daily peak-to-valley load difference by 6.08 %. In a real-world 10 kV feeder, the hybrid scheme reduces cumulative costs by 21.13 % compared with traditional scheme.

Authors

Institutions

Publication Details

Journal
International Journal of Electrical Power & Energy Systems
Published
2025-09-26
DOI
https://doi.org/10.1016/j.ijepes.2025.111187
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A hybrid planning framework for virtual capacity-enhanced distribution transformer considering time-division multiplexing of energy storage unit

Yuan Chi, Qianggang Wang, Yiyao Zhou, Niancheng Zhou et al.
International Journal of Electrical Power & Energy Systems
Microgrid Control and Optimization
article

A hybrid planning framework for virtual capacity-enhanced distribution transformer considering time-division multiplexing of energy storage unit

Yuan Chi, Qianggang Wang, Yiyao Zhou, Niancheng Zhou, Yao Zou, Luona Xu, Qingping Sun, Yongjie Luo
article en

Abstract

• A concept about virtual capacity-enhanced distribution transformer is proposed. • A hybrid planning framework is developed to determine the most economical and technically effective capacity-enhanced scheme. • A time-division multiplexing strategy is introduced to improve utilization of energy storage unit. • The peak-valley disparities and the “duck curve” phenomenon are addressed using the proposed method. Conventional (distribution transformers) DT capacity enhancement through replacement with larger units often incurs high investment costs and suboptimal asset utilization. To address these issues, this paper proposes a virtual capacity-enhanced scheme for DTs based on battery (energy storage unit) ESUs. A TDM strategy is introduced to improve ESU operation efficiency, and an optimal configuration model for ESU capacity is proposed to balance economic benefits and operational performance. A hybrid capacity-enhanced decision-making framework is further developed to guide DT capacity enhancement decisions by systematically evaluating virtual, conventional, and combined strategies. Case studies show that the virtual capacity-enhanced DT performs better under low overload conditions. Compared with traditional and purely virtual schemes, the hybrid scheme reduces five-year cumulative costs by 14.18 % and 11.61 %, respectively. In addition, the proposed TDM strategy increases the annual cumulative discharge duration of the ESU by 1233 h, and reduces the average daily peak-to-valley load difference by 6.08 %. In a real-world 10 kV feeder, the hybrid scheme reduces cumulative costs by 21.13 % compared with traditional scheme.

International Journal of Electrical Power & Energy SystemsVol. 172
Chongqing Normal University (CN), Chongqing University (CN), Chongqing University of Science and Technology (CN)
Openalex Percentile: Top 67%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.