Multicenter evaluation of the DEXTER® Robotic Surgery System for Total Hysterectomy with Adnexal Surgery

Minimally invasive hysterectomy is the preferred surgical approach for benign gynecologic conditions. The DEXTER® Robotic Surgery System was developed to address the limitations of conventional robotic systems, offering a mobile, modular, and accessible alternative adaptable to various surgical environments. This prospective, multicenter, single-arm study evaluated the clinical performance and early postoperative safety of the robotic-assisted hysterectomy with adnexal surgery for benign indications with DEXTER. The primary endpoints were short-term safety, assessed by the occurrence of Clavien-Dindo grade ≥ III adverse events up to 42 days postoperatively, and procedural success without conversion to laparoscopy or open surgery. Fifty-two patients were enrolled across four European centers-one university hospital and three community hospitals. All procedures were successfully completed without intraoperative complications or conversions. The mean total skin-to-skin operative time was 121.9 ± 42.7 min, and the mean estimated blood loss was 87.8 ± 93.8 mL. The system also demonstrated efficient setup with a mean docking time of 3.8 ± 1.3 min, as well as the feasibility of a three-trocar technique for minimal scarring and potential for outpatient application in select cases. The mean time to discharge was 2.0 ± 0.9 days. One major Clavien-Dindo IIIb complication occurred. No device-related adverse events were reported. These results confirm the safety and performance of DEXTER in robotic-assisted hysterectomy and support its role in expanding access to robotic-assisted surgery in diverse clinical settings.Trial registration: ClinicalTrials.gov NCT06473675.

Authors

Institutions

Publication Details

Journal
Journal of Robotic Surgery
Published
2025-09-26
DOI
https://doi.org/10.1007/s11701-025-02647-0
Citations
2
Primary Topic
Uterine Myomas and Treatments
Type
article
Field-Weighted Citation Impact
4.11
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multicenter evaluation of the DEXTER® Robotic Surgery System for Total Hysterectomy with Adnexal Surgery

Damaris Erhardt, Michael D. Mueller, Matthias Streich, Marie-Lucile Bodet et al.
2 citations
Journal of Robotic Surgery
Uterine Myomas and Treatments
4.11
article

Multicenter evaluation of the DEXTER® Robotic Surgery System for Total Hysterectomy with Adnexal Surgery

Damaris Erhardt, Michael D. Mueller, Matthias Streich, Marie-Lucile Bodet, Martin Heubner, Marietta Gulz, Anna Habegger, Borjana Bogdanovic
article en
2 citations

Abstract

Minimally invasive hysterectomy is the preferred surgical approach for benign gynecologic conditions. The DEXTER® Robotic Surgery System was developed to address the limitations of conventional robotic systems, offering a mobile, modular, and accessible alternative adaptable to various surgical environments. This prospective, multicenter, single-arm study evaluated the clinical performance and early postoperative safety of the robotic-assisted hysterectomy with adnexal surgery for benign indications with DEXTER. The primary endpoints were short-term safety, assessed by the occurrence of Clavien-Dindo grade ≥ III adverse events up to 42 days postoperatively, and procedural success without conversion to laparoscopy or open surgery. Fifty-two patients were enrolled across four European centers-one university hospital and three community hospitals. All procedures were successfully completed without intraoperative complications or conversions. The mean total skin-to-skin operative time was 121.9 ± 42.7 min, and the mean estimated blood loss was 87.8 ± 93.8 mL. The system also demonstrated efficient setup with a mean docking time of 3.8 ± 1.3 min, as well as the feasibility of a three-trocar technique for minimal scarring and potential for outpatient application in select cases. The mean time to discharge was 2.0 ± 0.9 days. One major Clavien-Dindo IIIb complication occurred. No device-related adverse events were reported. These results confirm the safety and performance of DEXTER in robotic-assisted hysterectomy and support its role in expanding access to robotic-assisted surgery in diverse clinical settings.Trial registration: ClinicalTrials.gov NCT06473675.

Journal of Robotic SurgeryVol. 19(1)
University Hospital of Bern (CH), Spital Linth (CH), Kantonsspital Baden (CH), Centre Hospitalier de Saint Jean de Dieu (FR), Med Discovery (Switzerland) (CH)
Openalex Percentile: Top 6%
Uterine Myomas and Treatments
4.11
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.