Multicenter Prospective Comparative Study of Patient Radiation Doses in Localization Techniques for Small Lung Lesions

<b>Background/Objectives:</b> Although surgeries employing cone-beam computed tomography (CBCT) for small lung lesions have been reported, the association between CBCT scan frequency and patient radiation exposure remains unclear. This study aimed to investigate patient radiation doses from CBCT during thoracic surgeries, and the patient radiation doses were compared with those from other preoperative marking methods. <b>Methods</b>: This multicenter prospective study included 81 patients who underwent surgery for small lung lesions requiring marking between January 2021 and June 2024 at three institutions. CBCT-guided surgeries involved the use of metal clips in a hybrid operating room with 1-4 scans, depending on the lesion. For other preoperative marking methods, hook-wire or virtual-assisted lung mapping (VAL-MAP) was used. Patient radiation doses were measured using wearable dosimeters at five anterior thorax sites, and the total dose was compared across methods. <b>Results</b>: The study included 81 patients: CBCT (<i>n</i> = 61), VAL-MAP (<i>n</i> = 10), and hook-wire (<i>n</i> = 10). CBCT cases were distributed as follows: single scan (<i>n</i> = 10), double scans (<i>n</i> = 34), triple scans (<i>n</i> = 15), and quadruple scans (<i>n</i> = 2). The radiation doses were 86.9 ± 61.7 mGy for hook-wire, 39.8 ± 27.5 mGy for VAL-MAP, and 11.0 ± 6.5 mGy for single-scan CBCT, 17.3 ± 7.8 mGy for double scans, 23.1 ± 14.0 mGy for triple scans, and 22.7 ± 0.1 mGy for quadruple scans. Although radiation exposure increased with more CBCT scans, performing up to triple scans resulted in significantly lower exposure compared to other methods. <b>Conclusions</b>: Intraoperative CBCT is a feasible and safe technique for identifying small lung lesions, providing lower radiation exposure compared to other preoperative localization methods.

Authors

Institutions

Publication Details

Journal
Cancers
Published
2025-09-25
DOI
https://doi.org/10.3390/cancers17193119
Primary Topic
Lung Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multicenter Prospective Comparative Study of Patient Radiation Doses in Localization Techniques for Small Lung Lesions

Takayuki Ibi, Yoshikane Yamauchi, Yukinori Sakao, Yuichi Saito et al.
Cancers
Lung Cancer Diagnosis and Treatment
article

Multicenter Prospective Comparative Study of Patient Radiation Doses in Localization Techniques for Small Lung Lesions

Takayuki Ibi, Yoshikane Yamauchi, Yukinori Sakao, Yuichi Saito, Takeshi Takata, Hisashi Takahashi, Tomoki Nishida, Yasuyuki Kanamoto, Tetsu Kanauchi, Nobumasa Takahashi, Ryuta Fukai, Shinya Kohmaru, Tomohiro Watanabe, Ikuo Kobayashi, Masafumi Kawamura, Hiroaki Morooka, Nobuo Yamaguchi, S Morita, Ryo Takeyama
article en

Abstract

<b>Background/Objectives:</b> Although surgeries employing cone-beam computed tomography (CBCT) for small lung lesions have been reported, the association between CBCT scan frequency and patient radiation exposure remains unclear. This study aimed to investigate patient radiation doses from CBCT during thoracic surgeries, and the patient radiation doses were compared with those from other preoperative marking methods. <b>Methods</b>: This multicenter prospective study included 81 patients who underwent surgery for small lung lesions requiring marking between January 2021 and June 2024 at three institutions. CBCT-guided surgeries involved the use of metal clips in a hybrid operating room with 1-4 scans, depending on the lesion. For other preoperative marking methods, hook-wire or virtual-assisted lung mapping (VAL-MAP) was used. Patient radiation doses were measured using wearable dosimeters at five anterior thorax sites, and the total dose was compared across methods. <b>Results</b>: The study included 81 patients: CBCT (<i>n</i> = 61), VAL-MAP (<i>n</i> = 10), and hook-wire (<i>n</i> = 10). CBCT cases were distributed as follows: single scan (<i>n</i> = 10), double scans (<i>n</i> = 34), triple scans (<i>n</i> = 15), and quadruple scans (<i>n</i> = 2). The radiation doses were 86.9 ± 61.7 mGy for hook-wire, 39.8 ± 27.5 mGy for VAL-MAP, and 11.0 ± 6.5 mGy for single-scan CBCT, 17.3 ± 7.8 mGy for double scans, 23.1 ± 14.0 mGy for triple scans, and 22.7 ± 0.1 mGy for quadruple scans. Although radiation exposure increased with more CBCT scans, performing up to triple scans resulted in significantly lower exposure compared to other methods. <b>Conclusions</b>: Intraoperative CBCT is a feasible and safe technique for identifying small lung lesions, providing lower radiation exposure compared to other preoperative localization methods.

CancersVol. 17(19)
University of Fukui (JP), Fukui University of Technology (JP), Teikyo University of Science (JP), Saitama Prefecture (JP), Teikyo University Hospital (JP), Shonan Kamakura General Hospital (JP), Teikyo University (JP)
Openalex Percentile: Top 62%
Lung Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.