iGFBP-1 Rapid Test Cassette (Vaginal Secretion): Performance Characteristics and Clinical Application in Detecting Rupture of Fetal Membranes

The iGFBP-1 Rapid Test Cassette (Vaginal Secretion) is a visually interpreted, qualitative immunochromatographic assay designed for the detection of insulin-like growth factor-binding protein 1 (iGFBP-1) in vaginal secretions of pregnant women. As a major protein marker of amniotic fluid, iGFBP-1 serves as an indicator for the diagnosis of rupture of fetal membranes (ROM). This study aims to do clinical studies of iGFBP-1 Rapid Test Cassette (Vaginal secretion) with the iGFBP-1 positive specimens and negative specimens which confirmed with other Rapid Test. A total of 230 vaginal swab specimens (100 iGFBP-1 positive and 130 iGFBP-1 negative, confirmed by another commercial iGFBP-1 rapid test) were analyzed. The results demonstrated high relative sensitivity (98.0%, 95%CI: 93.0%-99.8%), relative specificity (97.7%, 95%CI: 93.4%-99.5%) and overall accuracy (97.8%, 95%CI: 95.0%-99.3%). Intra-assay and inter-assay precision were excellent, with >99% correct identification of specimens across three lots. No cross-reactivity was observed with common vaginal microorganisms and no interference was detected from substances such as globulin, hemoglobin or bilirubin at clinically relevant concentrations. These findings indicate that the iGFBP-1 Rapid Test Cassette is a reliable, rapid, and practical tool for the qualitative detection of iGFBP-1 in vaginal secretions, aiding in the timely diagnosis of ROM and supporting clinical decision-making in obstetric care.

Publication Details

Journal
MEDS Clinical Medicine
Published
2025-01-01
DOI
https://doi.org/10.23977/medsc.2025.060419
Primary Topic
Prenatal Screening and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

iGFBP-1 Rapid Test Cassette (Vaginal Secretion): Performance Characteristics and Clinical Application in Detecting Rupture of Fetal Membranes

MEDS Clinical Medicine
Prenatal Screening and Diagnostics
article

iGFBP-1 Rapid Test Cassette (Vaginal Secretion): Performance Characteristics and Clinical Application in Detecting Rupture of Fetal Membranes

article en

Abstract

The iGFBP-1 Rapid Test Cassette (Vaginal Secretion) is a visually interpreted, qualitative immunochromatographic assay designed for the detection of insulin-like growth factor-binding protein 1 (iGFBP-1) in vaginal secretions of pregnant women. As a major protein marker of amniotic fluid, iGFBP-1 serves as an indicator for the diagnosis of rupture of fetal membranes (ROM). This study aims to do clinical studies of iGFBP-1 Rapid Test Cassette (Vaginal secretion) with the iGFBP-1 positive specimens and negative specimens which confirmed with other Rapid Test. A total of 230 vaginal swab specimens (100 iGFBP-1 positive and 130 iGFBP-1 negative, confirmed by another commercial iGFBP-1 rapid test) were analyzed. The results demonstrated high relative sensitivity (98.0%, 95%CI: 93.0%-99.8%), relative specificity (97.7%, 95%CI: 93.4%-99.5%) and overall accuracy (97.8%, 95%CI: 95.0%-99.3%). Intra-assay and inter-assay precision were excellent, with >99% correct identification of specimens across three lots. No cross-reactivity was observed with common vaginal microorganisms and no interference was detected from substances such as globulin, hemoglobin or bilirubin at clinically relevant concentrations. These findings indicate that the iGFBP-1 Rapid Test Cassette is a reliable, rapid, and practical tool for the qualitative detection of iGFBP-1 in vaginal secretions, aiding in the timely diagnosis of ROM and supporting clinical decision-making in obstetric care.

MEDS Clinical MedicineVol. 6(4)
Openalex Percentile: Top 63%
Prenatal Screening and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.