Determination of antibiotics in liquids by an amperometric sensor modified with a molecularly imprinted polymer

Amperometric sensors coated with MIPs were created for the determination of cefazolin sodium (Cef), neomycin sulfate (Neo) and sulfanilamide (Sulf) in liquid media with detection limits 1.5 × 10 –6 , 7.2 × 10 –6 , and 4.7 × 10 –6 g/dm 3 , respectively, which are below the maximum permissible concentrations of these antibiotics. The relative standard deviation ( S r ) is less than 4%, which indicates a high accuracy of the determination. The sensors demonstrated high selectivity with an imprinting factors ( IF ) 5.8 – 6.3 for the target compounds and low IF (<1.3) for other antibiotics. The accuracy and precision of MIP-Cef, MIP-Neo, and MIP-Sulf sensors was evaluated in the analysis of model solutions by the recovery test with S r not exceeding 5%, and by the reference methods of spectrophotometry and HPLC. The statistical analysis ( F -test and t -test) did not reveal significant differences, confirming the reliability of the method. The absence of the influence of other antibiotics on the results of Cef, Neo, and Sulf determination using MIP sensors was proved by analyzing model mixtures containing cefotaxime, ceftriaxone, and streptomycin. MIP sensors were tested in the analysis of cow milk: in all samples analysed residual content of all antibiotics (Cef, Neo, and Sulf) was not detected. Thus, the developed MIP sensors possess high sensitivity, selectivity, and accuracy, making them promising for monitoring antibiotic residues in water and food products.

Authors

Institutions

Publication Details

Journal
Industrial laboratory Diagnostics of materials
Published
2025-09-25
DOI
https://doi.org/10.26896/1028-6861-2025-91-9-28-35
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of antibiotics in liquids by an amperometric sensor modified with a molecularly imprinted polymer

Cao Nhat Linh, A. N. Zyablov, Thi Gam Pham, Anh Tien Nguyen
Industrial laboratory Diagnostics of materials
Analytical chemistry methods development
article

Determination of antibiotics in liquids by an amperometric sensor modified with a molecularly imprinted polymer

Cao Nhat Linh, A. N. Zyablov, Thi Gam Pham, Anh Tien Nguyen
article en

Abstract

Amperometric sensors coated with MIPs were created for the determination of cefazolin sodium (Cef), neomycin sulfate (Neo) and sulfanilamide (Sulf) in liquid media with detection limits 1.5 × 10 –6 , 7.2 × 10 –6 , and 4.7 × 10 –6 g/dm 3 , respectively, which are below the maximum permissible concentrations of these antibiotics. The relative standard deviation ( S r ) is less than 4%, which indicates a high accuracy of the determination. The sensors demonstrated high selectivity with an imprinting factors ( IF ) 5.8 – 6.3 for the target compounds and low IF (<1.3) for other antibiotics. The accuracy and precision of MIP-Cef, MIP-Neo, and MIP-Sulf sensors was evaluated in the analysis of model solutions by the recovery test with S r not exceeding 5%, and by the reference methods of spectrophotometry and HPLC. The statistical analysis ( F -test and t -test) did not reveal significant differences, confirming the reliability of the method. The absence of the influence of other antibiotics on the results of Cef, Neo, and Sulf determination using MIP sensors was proved by analyzing model mixtures containing cefotaxime, ceftriaxone, and streptomycin. MIP sensors were tested in the analysis of cow milk: in all samples analysed residual content of all antibiotics (Cef, Neo, and Sulf) was not detected. Thus, the developed MIP sensors possess high sensitivity, selectivity, and accuracy, making them promising for monitoring antibiotic residues in water and food products.

Industrial laboratory Diagnostics of materialsVol. 91(9)
Ho Chi Minh City University of Education (VN), International Center for Tropical Agriculture (VN), Voronezh State University (RU)
Openalex Percentile: Top 70%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Determination of antibiotics in liquids by an amperometric sensor modified with a molecularly imprinted polymer — Cao Nhat Linh, A. N. Zyablov, et al. · Industrial laboratory Diagnostics of materials (2025) | TGRS Research Map | TGRS