Reliability of Prediction Models for the Functional Classification of a Sinusoidal Intraocular Lens Depending on Pupil Diameter

<b>Background:</b> To assess the agreement among prediction models for the functional classification of intraocular lenses (IOLs) and discuss their limitations in evaluating pupil dependency of a sinusoidal IOL. <b>Methods:</b> An ISO-compliant optical bench setup with modifications to characterize the modulation transfer function area (MTFa) across pupil diameters from 1.5 to 5.5 mm was used to measure the Acriva Trinova Pro C Pupil Adaptive IOL. Six prediction models (Vega et al., 2018, Fernández et al., 2019, Alarcón et al., 2016, Armengol et al., 2020 were applied to estimate visual acuity defocus curves from MTFa and functional classification based on the depth-of-field (DOFi) and the increase in visual acuity (ΔVA) from intermediate to near. <b>Results:</b> Defocus curves for all prediction models consistently demonstrated a Full-DOFi response (>2.3 D at 0.2 logMAR), with differences in ΔVA emerging across pupil diameters. Continuous decreases (ΔVA < 0.05 logMAR) were observed at pupil diameters <2.5 mm, while Smooth transitions (ΔVA from 0.05 to 0.14 logMAR) occurred between 2.5-3.0 mm for all models except for Vega. At pupil diameters >3.5 mm, most models transitioned to a Steep classification (ΔVA ≥ 0.14 logMAR), except Fernández, which remained Smooth, and Armengol 2020a, which shifted to Steep at 4.0 mm. <b>Conclusions:</b> Visual acuity prediction models provide useful means of reporting optical bench data in clinically familiar metrics. However, outcomes should be interpreted with caution as functional classifications can vary depending on the optical bench setup and prediction model used.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2025-09-25
DOI
https://doi.org/10.3390/diagnostics15192446
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliability of Prediction Models for the Functional Classification of a Sinusoidal Intraocular Lens Depending on Pupil Diameter

Walter D. Furlan, Diego Montagud-Martínez, Vicente Ferrando, Manuel Rodríguez‐Vallejo et al.
Diagnostics
Intraocular Surgery and Lenses
article

Reliability of Prediction Models for the Functional Classification of a Sinusoidal Intraocular Lens Depending on Pupil Diameter

Walter D. Furlan, Diego Montagud-Martínez, Vicente Ferrando, Manuel Rodríguez‐Vallejo, Joaquín Fernández
article en

Abstract

<b>Background:</b> To assess the agreement among prediction models for the functional classification of intraocular lenses (IOLs) and discuss their limitations in evaluating pupil dependency of a sinusoidal IOL. <b>Methods:</b> An ISO-compliant optical bench setup with modifications to characterize the modulation transfer function area (MTFa) across pupil diameters from 1.5 to 5.5 mm was used to measure the Acriva Trinova Pro C Pupil Adaptive IOL. Six prediction models (Vega et al., 2018, Fernández et al., 2019, Alarcón et al., 2016, Armengol et al., 2020 were applied to estimate visual acuity defocus curves from MTFa and functional classification based on the depth-of-field (DOFi) and the increase in visual acuity (ΔVA) from intermediate to near. <b>Results:</b> Defocus curves for all prediction models consistently demonstrated a Full-DOFi response (>2.3 D at 0.2 logMAR), with differences in ΔVA emerging across pupil diameters. Continuous decreases (ΔVA < 0.05 logMAR) were observed at pupil diameters <2.5 mm, while Smooth transitions (ΔVA from 0.05 to 0.14 logMAR) occurred between 2.5-3.0 mm for all models except for Vega. At pupil diameters >3.5 mm, most models transitioned to a Steep classification (ΔVA ≥ 0.14 logMAR), except Fernández, which remained Smooth, and Armengol 2020a, which shifted to Steep at 4.0 mm. <b>Conclusions:</b> Visual acuity prediction models provide useful means of reporting optical bench data in clinically familiar metrics. However, outcomes should be interpreted with caution as functional classifications can vary depending on the optical bench setup and prediction model used.

DiagnosticsVol. 15(19)
Universitat de València (ES), Universitat Politècnica de València (ES)
European Commission
Openalex Percentile: Top 61%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.