Optimization of gain calibration in NectarCAM: evaluating the impact of charge extraction methods

The NectarCAM is a camera designed for the Medium Sized Telescopes (MSTs) of the northern site of the Cherenkov Telescope Array Observatory. The NectarCAM camera equipping the MSTs is sensitive to gamma rays in the energy range of approximately 100 GeV to 10 TeV. The camera consists of 1,855 pixels, grouped into modules of 7 pixels each. To accurately reconstruct real data acquisitions, several calibration steps are required. Among them, gain calibration is crucial, as it ensures the conversion of the electronic signal detected by each pixel into a corresponding number of photo-electrons. This calibration can be performed using dedicated systems at the camera integration facility and on site. The full calibration of the camera is carried out with nectarchain, a software framework based on ctapipe. Within this framework, two different methods can be applied to compute the gain. Additionally, multiple charge extraction methods can be used to process the electronic signal in each pixel. In this study, we conduct a quantitative analysis of the impact of different charge extraction methods on gain computation for the entire camera. This allows us to determine the optimal procedure for achieving reliable and accurate gain calibration.

Authors

Publication Details

Published
2025-09-23
DOI
https://doi.org/10.22323/1.501.0667
Primary Topic
CCD and CMOS Imaging Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of gain calibration in NectarCAM: evaluating the impact of charge extraction methods

P. Jean, G. Grolleron, F. Brun, J.-P. Lenain
CCD and CMOS Imaging Sensors
article

Optimization of gain calibration in NectarCAM: evaluating the impact of charge extraction methods

P. Jean, G. Grolleron, F. Brun, J.-P. Lenain
article en

Abstract

The NectarCAM is a camera designed for the Medium Sized Telescopes (MSTs) of the northern site of the Cherenkov Telescope Array Observatory. The NectarCAM camera equipping the MSTs is sensitive to gamma rays in the energy range of approximately 100 GeV to 10 TeV. The camera consists of 1,855 pixels, grouped into modules of 7 pixels each. To accurately reconstruct real data acquisitions, several calibration steps are required. Among them, gain calibration is crucial, as it ensures the conversion of the electronic signal detected by each pixel into a corresponding number of photo-electrons. This calibration can be performed using dedicated systems at the camera integration facility and on site. The full calibration of the camera is carried out with nectarchain, a software framework based on ctapipe. Within this framework, two different methods can be applied to compute the gain. Additionally, multiple charge extraction methods can be used to process the electronic signal in each pixel. In this study, we conduct a quantitative analysis of the impact of different charge extraction methods on gain computation for the entire camera. This allows us to determine the optimal procedure for achieving reliable and accurate gain calibration.

Openalex Percentile: Top 74%
CCD and CMOS Imaging Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.