A multinational study of deep learning-based image enhancement for multiparametric glioma MRI

This study aimed to validate the utility of commercially available vendor-neutral deep learning (DL) image enhancement software for improving the image quality of multiparametric MRI for gliomas in a multinational setting. A total of 294 patients from three institutions (NYU, Severance, and SNUH) who underwent glioma MRI protocols were included in this retrospective study. DL image enhancement was performed on T2-weighted (T2W), T2 FLAIR, and postcontrast T1-weighted (T1W) imaging using commercially available DL image enhancement software. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated for both conventional and DL-enhanced images. Three neuroradiologists, one from each institution, independently evaluated the following image quality parameters in both images using a 5-point scale: overall image quality, noise, gray-white matter differentiation, truncation artifact, motion artifact, pulsation artifact, and main lesion conspicuity. The quantitative and qualitative image parameters were compared between conventional and DL-enhanced images. Compared with conventional images, DL-enhanced images showed significantly higher SNRs and CNRs in T2W, T2 FLAIR, and postcontrast T1W imaging (all P < 0.001). The average scores of radiologist assessments in overall image quality, noise, gray-white matter differentiation, and main lesion conspicuity were significantly higher for DL-enhanced images than conventional images in T2W, T2 FLAIR, and postcontrast T1W imaging (all P < 0.001). Regarding artifacts, truncation artifacts decreased (all P < 0.001), while pre-existing motion and pulsation artifacts were not further exaggerated in most structural MRI sequences. In conclusion, DL image enhancement using commercially available vendor-neutral software improved image quality and reduced truncation artifacts in multiparametric glioma MRI.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-09-25
DOI
https://doi.org/10.1038/s41598-025-17993-0
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A multinational study of deep learning-based image enhancement for multiparametric glioma MRI

Rajan Jain, Kuldeep Singh, Roh‐Eul Yoo, Yae Won Park et al.
Scientific Reports
Radiomics and Machine Learning in Medical Imaging
article

A multinational study of deep learning-based image enhancement for multiparametric glioma MRI

Rajan Jain, Kuldeep Singh, Roh‐Eul Yoo, Yae Won Park, Geunu Jeong, Sung Soo Ahn, Kyunghwa Han, Kevin Yang, Young Hun Jeon, Leeha Ryu, Sohyun Kim, Min Young Lee, Seung‐Koo Lee, Ilah Shin, Seung Hong Choi
article en

Abstract

This study aimed to validate the utility of commercially available vendor-neutral deep learning (DL) image enhancement software for improving the image quality of multiparametric MRI for gliomas in a multinational setting. A total of 294 patients from three institutions (NYU, Severance, and SNUH) who underwent glioma MRI protocols were included in this retrospective study. DL image enhancement was performed on T2-weighted (T2W), T2 FLAIR, and postcontrast T1-weighted (T1W) imaging using commercially available DL image enhancement software. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated for both conventional and DL-enhanced images. Three neuroradiologists, one from each institution, independently evaluated the following image quality parameters in both images using a 5-point scale: overall image quality, noise, gray-white matter differentiation, truncation artifact, motion artifact, pulsation artifact, and main lesion conspicuity. The quantitative and qualitative image parameters were compared between conventional and DL-enhanced images. Compared with conventional images, DL-enhanced images showed significantly higher SNRs and CNRs in T2W, T2 FLAIR, and postcontrast T1W imaging (all P < 0.001). The average scores of radiologist assessments in overall image quality, noise, gray-white matter differentiation, and main lesion conspicuity were significantly higher for DL-enhanced images than conventional images in T2W, T2 FLAIR, and postcontrast T1W imaging (all P < 0.001). Regarding artifacts, truncation artifacts decreased (all P < 0.001), while pre-existing motion and pulsation artifacts were not further exaggerated in most structural MRI sequences. In conclusion, DL image enhancement using commercially available vendor-neutral software improved image quality and reduced truncation artifacts in multiparametric glioma MRI.

Scientific ReportsVol. 15(1)
Seoul National University (KR), Yonsei University (KR), Seoul National University Hospital (KR), National University (SD), The Catholic University of Korea Seoul St. Mary's Hospital (KR), New York University (US), Korea Air Force Academy (KR)
Korea Medical Device Development Fund, National Research Foundation, Ministry of Trade, Industry and Energy, Ministry of Food and Drug Safety, Korea Basic Science Institute, National Research Foundation of Korea, Institute for Basic Science, Ministry of Science and ICT, South Korea, Samsung
Openalex Percentile: Top 61%
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.