Transient Operational Characteristics of a Dual Compensation Chamber Loop Heat Pipe Without the Bayonet for Avionics Cooling

Abstract The removal of bayonet structures reduces the manufacturing complexity of loop heat pipes. This study investigates the transient characteristics of a newly designed dual compensation chamber loop heat pipe (DCCLHP) without a bayonet in high acceleration fields and analyzes instability phenomena. This work was conducted under four typical installation orientations, accelerations of 3–15 g, heat loads of 20–450 W, and heat sink temperatures of 15–25 ℃. Results demonstrate that the absence of the bayonet does not significantly degrade DCCLHP performance. Even at the unfavorable Orientation I, the system successfully starts up at 15 g and 20 W while maintaining stable operation at 6 g and 450 W. The acceleration direction significantly influences operational characteristics. Although favorable for liquid return, excessive acceleration may amplify the temperature difference between the two compensation chambers, thereby elevating the evaporator temperature. Notably, the DCCLHP may maintain satisfactory performance under high heat loads at the unfavorable Orientation IV. Additionally, several instability phenomena are observed. Vapor–liquid redistribution may induce evaporator temperature rise in a period of time, and the acceleration magnitude alters the minimum heat load, triggering this redistribution. Temperature oscillations occur only under specific conditions, with higher accelerations causing oscillatory behaviors. Temperature overshoot manifests mainly under lower heat loads and orientations favorable for liquid return, while increasing acceleration magnitude tends to weaken the overshoot. These findings provide critical data support and technical insights for the simplified design of DCCLHPs and their practical applications in aircraft.

Authors

Institutions

Publication Details

Journal
Journal of Thermal Science and Engineering Applications
Published
2025-09-25
DOI
https://doi.org/10.1115/1.4069968
Primary Topic
Heat Transfer and Boiling Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transient Operational Characteristics of a Dual Compensation Chamber Loop Heat Pipe Without the Bayonet for Avionics Cooling

Yongqi Xie, Longzhu Han, Zhen Fang, Hongwei Wu et al.
Journal of Thermal Science and Engineering Applications
Heat Transfer and Boiling Studies
article

Transient Operational Characteristics of a Dual Compensation Chamber Loop Heat Pipe Without the Bayonet for Avionics Cooling

Yongqi Xie, Longzhu Han, Zhen Fang, Hongwei Wu, Lijun Chen
article en

Abstract

Abstract The removal of bayonet structures reduces the manufacturing complexity of loop heat pipes. This study investigates the transient characteristics of a newly designed dual compensation chamber loop heat pipe (DCCLHP) without a bayonet in high acceleration fields and analyzes instability phenomena. This work was conducted under four typical installation orientations, accelerations of 3–15 g, heat loads of 20–450 W, and heat sink temperatures of 15–25 ℃. Results demonstrate that the absence of the bayonet does not significantly degrade DCCLHP performance. Even at the unfavorable Orientation I, the system successfully starts up at 15 g and 20 W while maintaining stable operation at 6 g and 450 W. The acceleration direction significantly influences operational characteristics. Although favorable for liquid return, excessive acceleration may amplify the temperature difference between the two compensation chambers, thereby elevating the evaporator temperature. Notably, the DCCLHP may maintain satisfactory performance under high heat loads at the unfavorable Orientation IV. Additionally, several instability phenomena are observed. Vapor–liquid redistribution may induce evaporator temperature rise in a period of time, and the acceleration magnitude alters the minimum heat load, triggering this redistribution. Temperature oscillations occur only under specific conditions, with higher accelerations causing oscillatory behaviors. Temperature overshoot manifests mainly under lower heat loads and orientations favorable for liquid return, while increasing acceleration magnitude tends to weaken the overshoot. These findings provide critical data support and technical insights for the simplified design of DCCLHPs and their practical applications in aircraft.

Journal of Thermal Science and Engineering ApplicationsVol. 18(1)
University of Hertfordshire (GB), Beijing Haidian Hospital (CN), Beihang University (CN)
Openalex Percentile: Top 73%
Heat Transfer and Boiling Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.