Reusable terahertz metasurface microfluidic sensor with enhanced sensitivity for trace liquid analysis

This study presents a reusable, high-sensitivity terahertz (THz) metasurface sensor integrated with a 4.1 µm ultra-thin microfluidic channel to address the critical challenges of low sensitivity and trace solution detection in conventional THz sensing platforms. Through comprehensive numerical simulations and experimental validation, we demonstrate a sensor achieving 0.565 THz/RIU sensitivity for minute analyte volumes (0.4 µL), representing a 2.58-to-5.64-fold enhancement over conventional THz metasurface structures. The measured resonance frequency shifts (Δ<i>f</i>) for 0.4 µL of ethanol, methanol, glycerin, and water were 363 GHz, 400 GHz, 475 GHz, and 623 GHz, respectively, with excellent agreement between experimental and simulation results. This work significantly advances THz sensing technology by enabling high-sensitivity detection of both polar and non-polar trace analytes, with important implications for biochemical sensing and aqueous solution analysis.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2025-09-25
DOI
https://doi.org/10.1364/oe.575143
Citations
2
Primary Topic
Photonic and Optical Devices
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reusable terahertz metasurface microfluidic sensor with enhanced sensitivity for trace liquid analysis

Dingbang Liu, Mingyao Gao, Yusa Chen, Shengxiao Jin et al.
2 citations
Optics Express
Photonic and Optical Devices
1.46
article

Reusable terahertz metasurface microfluidic sensor with enhanced sensitivity for trace liquid analysis

Dingbang Liu, Mingyao Gao, Yusa Chen, Shengxiao Jin, Yunhao Cao, Hongshun Sun, Shuai Wang, Wengang Wu, Lijun Ma
article en
2 citations

Abstract

This study presents a reusable, high-sensitivity terahertz (THz) metasurface sensor integrated with a 4.1 µm ultra-thin microfluidic channel to address the critical challenges of low sensitivity and trace solution detection in conventional THz sensing platforms. Through comprehensive numerical simulations and experimental validation, we demonstrate a sensor achieving 0.565 THz/RIU sensitivity for minute analyte volumes (0.4 µL), representing a 2.58-to-5.64-fold enhancement over conventional THz metasurface structures. The measured resonance frequency shifts (Δ<i>f</i>) for 0.4 µL of ethanol, methanol, glycerin, and water were 363 GHz, 400 GHz, 475 GHz, and 623 GHz, respectively, with excellent agreement between experimental and simulation results. This work significantly advances THz sensing technology by enabling high-sensitivity detection of both polar and non-polar trace analytes, with important implications for biochemical sensing and aqueous solution analysis.

Optics ExpressVol. 33(21)
Space Micro (United States) (US)
Openalex Percentile: Top 15%
Photonic and Optical Devices
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.