Insertion Loss Requirement and Low Level PCI Testing of HEMP Power Line Filter

High Altitude Electromagnetic Pulse (HEMP) power line filters are used to suppress the conducted HEMP on the power lines of a facility. The insertion loss requirement, however, is not very clear in any of the public standards related to HEMP. MIL-STD-188-125 1/2 requires Pulsed Current Injection (PCI) verification testing for filters and specifies maximum limits for norms of the measured residual internal transient currents and shielding requirements of a facility. IEEE-STD-1560 specifies how to test a filter for RF characteristic test, mismatched impedance, attenuation measurements (100 kHz to 30 MHz), S-parameter measurement up to 30 MHz and aperture leak testing by electric fields (1 GHz to 10 GHz). However, the conducted HEMP contains its maximum frequency content up to 50 MHz, where most of the pulse energy is concentrated. This paper aims to investigate the upper frequency range of insertion loss specifications for HEMP power line filters to ensure their effectiveness across all possible conducted environments. Additionally, low-level (1 kA) PCI testing is explored as a pre-compliance measure for HEMP filter design and performance verification.

Authors

Institutions

Publication Details

Published
2025-08-18
DOI
https://doi.org/10.1109/emcsipi52291.2025.11169788
Primary Topic
Electromagnetic Compatibility and Noise Suppression
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Insertion Loss Requirement and Low Level PCI Testing of HEMP Power Line Filter

Rakesh Kichouliya, Saurabh Kichouliya, S.M. Satav
Electromagnetic Compatibility and Noise Suppression
article

Insertion Loss Requirement and Low Level PCI Testing of HEMP Power Line Filter

Rakesh Kichouliya, Saurabh Kichouliya, S.M. Satav
article en

Abstract

High Altitude Electromagnetic Pulse (HEMP) power line filters are used to suppress the conducted HEMP on the power lines of a facility. The insertion loss requirement, however, is not very clear in any of the public standards related to HEMP. MIL-STD-188-125 1/2 requires Pulsed Current Injection (PCI) verification testing for filters and specifies maximum limits for norms of the measured residual internal transient currents and shielding requirements of a facility. IEEE-STD-1560 specifies how to test a filter for RF characteristic test, mismatched impedance, attenuation measurements (100 kHz to 30 MHz), S-parameter measurement up to 30 MHz and aperture leak testing by electric fields (1 GHz to 10 GHz). However, the conducted HEMP contains its maximum frequency content up to 50 MHz, where most of the pulse energy is concentrated. This paper aims to investigate the upper frequency range of insertion loss specifications for HEMP power line filters to ensure their effectiveness across all possible conducted environments. Additionally, low-level (1 kA) PCI testing is explored as a pre-compliance measure for HEMP filter design and performance verification.

Research Centre Imarat (IN), Indian Institute of Science Bangalore (IN)
Openalex Percentile: Top 74%
Electromagnetic Compatibility and Noise Suppression
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.