Comparison Study of Cuff Electrode Designs on RF-Induced Heating Under MRI

This study explores the influence of cuff electrode design, including variations in diameter and wrapping angle, on implantable medical device RF-induced heating under MRI procedure. Numerical and experimental studies were performed to evaluate the heating variation due to these factors inside the ASTM phantom. The results highlight that electrode design can significantly impact heating. It was observed that electrodes with smaller diameters and smaller wrapping angles can have higher RF-induced heating. It was also observed that the electrode designs will not change the shape of the device model. These findings provide critical insights for efficient and safer designs for cuff electrode.

Authors

Institutions

Publication Details

Published
2025-08-18
DOI
https://doi.org/10.1109/emcsipi52291.2025.11170198
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison Study of Cuff Electrode Designs on RF-Induced Heating Under MRI

Yuhui Xu, Jianfeng Zheng, Qingyan Wang, Ji Chen et al.
Advanced MRI Techniques and Applications
article

Comparison Study of Cuff Electrode Designs on RF-Induced Heating Under MRI

Yuhui Xu, Jianfeng Zheng, Qingyan Wang, Ji Chen, Lijian Yang, Ebrahimi Farshad
article en

Abstract

This study explores the influence of cuff electrode design, including variations in diameter and wrapping angle, on implantable medical device RF-induced heating under MRI procedure. Numerical and experimental studies were performed to evaluate the heating variation due to these factors inside the ASTM phantom. The results highlight that electrode design can significantly impact heating. It was observed that electrodes with smaller diameters and smaller wrapping angles can have higher RF-induced heating. It was also observed that the electrode designs will not change the shape of the device model. These findings provide critical insights for efficient and safer designs for cuff electrode.

University of Houston (US)
Openalex Percentile: Top 61%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison Study of Cuff Electrode Designs on RF-Induced Heating Under MRI — Yuhui Xu, Jianfeng Zheng, et al. · (2025) | TGRS Research Map | TGRS